A. Appendix
117
Advanced - Advanced Configuration - Wired LAN Configuration
Link Speed
Details
Sets the link speed for the wired network.
Usually, "
AUTO
" is used.
Range
AUTO / 10BASE-T-Half / 10BASE-T-Full / 100BASE-TX-Half / 100BASE-TX-Full
Default Value
AUTO
Note
If a LINK LED on the connected device does not light on when BR-500AC is
powered on, change the network type to that of the connected device.
Advanced - Advanced Configuration - Wireless LAN Configuration
Roaming Threshold(dBm)
Details
Set the roaming threshold value (-35 to -95).
If a greater value is set, frequency of roaming is increased, however,
communication may become unstable.
Range
-35 to -95
Default Value
-75
Note
A time of roaming may take longer depending on the combination with other
settings of BR-500AC.
WME Default Access Category
Details
Set the access category to use for wireless communication when there is no
priority setting for communication from the connected wired device.
Range
DISABLE (AC_BE) / AC_BK / AC_VI / AC_VO
Default Value
DISABLE (AC_BE)
Note
The priority differs depending on the access category to set.
Order of priority: (1)
AC_VO
(audio) (2)
AC_VI
(video) (3)
AC_BE
(best effort)
(4)
AC_BK
(background)
Login Password - Password Configuration
Please input the password.
Details
Configure the password to manage the BR-500AC.
This password is used for authentication to login to the Web configuration
interface of BR-500AC.
Range
1 - 8 characters
Default Value
(None)
Summary of Contents for BR-500AC
Page 1: ...Wireless Bridge BR 500AC User s Manual...
Page 2: ...Copyright 2021 silex technology Inc All rights reserved WA106560XA...
Page 6: ...Blank page...
Page 12: ...6 BR 500AC User s Manual Blank page...
Page 24: ...18 BR 500AC User s Manual Blank page...
Page 58: ...52 BR 500AC User s Manual Blank page...
Page 98: ...92 BR 500AC User s Manual 3 Click Submit...
Page 100: ...94 BR 500AC User s Manual 2 Select the default access category to use and click Submit...