REKORD
Operating manual - English
24
Copyright Silca 2 007
8.7
Access to the lower part
ATTENTION: remove the mains plug.
1) Detach the wire from the key-cutting machine socket.
2) Remove the double box (tool holder/swarf tray) (C) and (C1).
3) Turn the machine over onto its back.
4) Loosen the 6 screws (Y) to remove the bottom grate.
Fig. 28
8.8
Replacing main switch
ATTENTION: remove the mains plug.
1) Access the bottom part (see ch. 8.7).
2) Detach the 4 connectors (Y1) paying special attention to their position.
3) Use a screwdriver to lower the internal tabs fixing the switch, then pull it out.
4) Fit the new main switch.
5) Reconnect the 4 connectors (Y1).
6) Replace the bottom grate and secure with the screws (Y) (fig. 28).
7) Turn the machine back into place on the work bench.
Fig. 29
Y
Y1