REKORD
Operating manual - English
26
Copyright Silca 2 007
Fig. 34
8.10
Replacing lamp feed (transformer)
ATTENTION: remove the mains plug.
1) Access the bottom part (see ch. 8.7).
2) Loosen the 2 low voltage connector screws (Q1) remove and place in their seat on the new transfor-
mer, securing with the 2 screws.
3) Loosen the 2 mains connector screws (Q3) remove and place in their seat on the new transformer,
securing with the 2 screws.
4) Loosen the screws (Q2) fixing the transformer to the bottom plate and remove.
5) Place the new transformer in position and secure with the screws (Q2).
6) Replace the bottom grate and secure with the screws (Y) (fig.28, page 24).
7) Place the machine in position on the work bench.
Fig. 35
Fig. 36
8.11
Replacing lamp set/lamp protection
Lamp set
ATTENTION: remove the mains plug.
1) Remove the two protective pads (Q).
2) Loosen the 3 screws (M1) and remove the top cover (M).
3) Access the bottom part (see ch. 8.7).
4) Loosen the 2 low voltage connector screws (Q1) and remove them.
5) Position the machine upright again.
6) Loosen the 2 lamp fixing screws (L1) and remove.
7) Replace the top cover and secure with the 3 screws (M1).
8) Turn the machine over onto its back.
9) Connect the 2 connectors in the low voltage supply outlet seat and secure with the 2 screws (Q1).
10) Replace the bottom grate and secure with the screws (Y) (fig. 28).
11) Place the machine in position on the work bench.
S5
Q1
Q2