Replacing lamp feed (transformer)
ATTENTION: turn off the machine and disconnect the supply wire.
1) Access the bottom part (see ch. 8.6).
2) Loosen the 2 low voltage connector screws (Q1) remove and place in their seat on the new
transformer, securing with the 2 screws.
3) Loosen the 2 mains connector screws (Q3) remove and place in their seat on the new transformer,
securing with the 2 screws.
4) Loosen the screws (Q2) fixing the transformer to the bottom plate and remove.
5) Place the new transformer in position and secure with the screws (Q2).
6) Replace the bottom grate and secure with the screws (Y) (fig.27, page 19).
7) Place the machine in position on the work bench.
Fig. 34
Fig. 35
Z
X
X1
S4
S5
Q1
Q3
Q2