6-102
DC2 '{' a n m
User Area Data Registration/Clears
Code
12H 7BH a n m
Function Registers/Clears data in the external RAM to the FLASH memory.
a = Data types (00H to 05H)
n = Data ID
m = Registers/Clears data (*******1B: registers, *******0B: clears)
When the least significant bit of m is set as 1, the printer registers data in the external RAM to the
FLASH memory. If selected data by a already has been registered into the FLASH memory, the
printer deletes registered data and registers new one.
When the least significant bit of m is set as 0, the printer clears selected data by a in the FLASH
memory.
Specify data types as a.
a=0: Downloaded characters
a=1: User-defined characters
a=2: Optional fonts
a=3:
Stamp
a=4: Routine format
a=5: Routine parameter
Specify data ID as n.
a=3 selected: Stamp number
a=4 selected: Routine format number
a=5 selected: Routine parameter number
When selecting a as 0 to 2, the value of n is ignored.
The FLASH memory life is shortened if this command is used many times. The FLASH memory
life: Approx.100000 times.
DC2 '*' '1'
User Area Defragment
Code
12H 2AH 31H
Function The printer performs the FLASH memory allocation again and keeps memory area.
Note
The FLASH memory capacity cannot be increased by area control related commands.
The released memory by area control can be used again by this command.
The FLASH memory life is shortened if this command is used many times. The FLASH memory
life: Approx.100000 times.
DC2 '*' '2'
Remaining User Area Response
Code
12H 2AH 32H
Function Checks the remaining memory capacity of the FLASH memory. The remaining memory capacity
in the FLASH memory is responded with 6-byte by hexadecimal number.
Note
The remaining capacity in the FLASH memory cannot be increased by commands related to
registration and release of the registered area.
Executing User Area Defragment (DC2
'1') command can increase the remaining FLASH
memory capacity.
Summary of Contents for DPU-S245
Page 1: ...DPU S245 SERIES THERMAL PRINTER TECHNICAL REFERENCE U00117152801 ...
Page 12: ...2 2 Dimensions 83 130 45 1 3 63 5 75 2 9 7 38 Unit mm Figure 2 1 Dimensions Paper Outlet ...
Page 87: ...6 42 Figure 6 10 Print Sample 5 ...
Page 97: ...6 52 Figure 6 12 Print Sample 6 ...
Page 122: ...6 77 Figure 6 24 Print Sample 12 ...
Page 125: ...6 80 Figure 6 28 Print Sample 14 ...