4-2
4.1.1 Function
Settings(SWDIP1)
Table 4-1 Function Settings (SWDIP1)
Value
SWDIP Function
0 1
1-8 Data
Control
Xon/Xoff
Busy
1-7
Stop Bit
2 bits
1 bit
1-6
1-5
Parity
See table below
1-4
Bit Length
7 bits
8 bits
1-3
1-2
1-1
Baud Rate
See table below
Data Control selection
Select flow control in serial communication as BUSY (hardware) control or Xon/Xoff control.
In BUSY control, flow control is performed using RTS signal in the printer.
In Xon/Xoff control, flow control is performed using codes of Xon(11H) or Xoff(13H) from the printer.
Stop Bit selection
Select Stop Bit in serial communication as 1 bit or 2 bits.
Parity selection
Select Parity in serial communication as Even, Odd or None.
Parity SWDIP1-
6
SWDIP1-5
None
0
0
Odd 0
1
None 1
0
Even 1
1
Bit Length selection
Select Bit Length in serial communication as 8 or 7 bits.