Cable Error
Messages
Opens
The tester displays OPEN if it does not sense an interconnection that should exist in the cable.
For example, if this is correct
and this was the error, the error would display like this.
If the User Preference
Fault Location
were turned on, the open above would be
displayed like this.
An asterisk is added to the pin closest to
the open. The tester can do this by
sensing the lower capacitance of the
unconnected pin.
Opens are caused by:
Defects in the cable, such as missing or cut wires, defective or un-inserted connector
contacts, and cold solder joints.
The
LV Insulation Resistance
setting being set lower than the actual resistance of a
wire connection.
The
Component Resistance
setting being set lower than an electronic component in
the cable.
Miswires
The tester displays MISWIRE if it senses that a contact, which should have a valid connection, is
connected to an incorrect contact.
As shown in this example, the miswire error is indicated as a contact OPEN to where it
should
go, and MISWIRE to where it
does
go.
Miswires are caused by:
Wiring errors in the cable.
ERROR:E8C464-2X8NH
NET 1: OPEN
J1-001 TO J3-001
MISWIRE J3-002
NET 1
NET 2
1
2
1
2
J3
J1
J1
1
2
J3
pr
ob
e
1
2
ERROR:E8C464-2X8NH
NET 2: OPEN
J1-002 TO J3-002
MISWIRE J3-001
ERROR: 1C4873-2X8NH
NET 2: OPEN
J1-002 TO J3-002
NET 1
1
2
J1
1
2
J3
pr
ob
e
NET 1
NET 2
1
2
1
2
J3
J1
and these were the errors,
the error message would look like this.
For example, if this is correct
ERROR: 1C4873-2X8NH
NET 2: OPEN
* J1-002 TO J3-002