Testing a Cable
1. Make sure the test program for the cable
being tested is loaded.
Load a different test program by:
Creating a test from a sample cable
OR
Retrieving a test from memory.
2. Duplicate the adapter setup from the
original test.
To remember the original adapter positions:
Refer to the documentation used for
the test
OR
Press
Test
for the loaded test
program.
Press
Show Required List
.
1100R+ Cable Documentation
Cable Signature: 39E92F-4Z020
J1 Adapter Signature: F5B4E0
J2 Adapter Signature: 03FAC1
Connection Resistance: <Auto .5
Insulation Resistance: 50M
3. Attach the cable to be tested and start
the test:
If you have not done this already,
press
Test
for the loaded test
program
.
Attach the first cable to be tested.
Note:
If the User Preference
Test Mode
is set to CONTINUOUS, the test will start automatically.
If
Test Mode
is set to SINGLE
TEST,
press
START TEST to begin the test. For more information,
see
Test Mode
on page
36.
Adapters set up in
original positions
The last loaded
test program is
displayed on the
main menu after
learning a cable.
CABLE LEARNED
Verify Test
Save Test
Test: 39E92F-4Z020