43
Low Voltage
Settings
LV Insulation Resistance
(LV Insul Res)
The
LV Insulation Resistance
setting only affects the low voltage test where the basic cable
pattern and gross insulation problems are identified. This setting determines how high the
insulation resistance must be between cable nets to pass the low voltage test. The tester
displays SHORT for an unintended resistance between nets that is less than the
LV Insulation
Resistance
setting.
In addition, the
LV Insulation Resistance
setting determines at what resistance
intended
connections are considered
open
,
as opposed to having high resistance.
Guidelines on LV Insulation Resistance
The factory default of 100K
Ω should work well for most cable testing applications. The higher
you raise
the
LV Insulation Resistance
setting, the longer it takes for the tester to perform the
low voltage part of the cable test.
Note:
Resistances above the
LV Insulation Resistance
setting will be ignored during a learn.
Selections
Factory Default
0.1
Ω-100KΩ,
500KΩ, 1MΩ, 5MΩ
100KΩ
Zero
Resistance
LV Insulation
Resistance
Setting
Infinite
Resistance
Connection
Resistance
Setting
Zero
Resistance
LV Insulation
Resistance
Setting
Infinite
Resistance
PASSES LV
SHORT
PASSES LV
SHORT
HIGH RESISTANCE
GOOD
OPEN
Summary of Contents for 1100R+