Chapter 11
| Interface Commands
– 363 –
low-alarm
– Sets the low temperature threshold for an alarm
message.
low-warning
– Sets the low temperature threshold for a warning
message.
threshold-value
– The threshold of the transceiver temperature.
(Range: -12800 - 12800 in units of 0.01 Celsius)
Default Setting
High Alarm: 75.00
C
HIgh Warning: 70.00
C
Low Alarm:-123.00
C
Low Warning: 0.00
C
Command Mode
Interface Configuration (SFP+ Ports)
Command Usage
◆
Refer to the Command Usage section under the
command for more information on configuring transceiver
thresholds.
◆
Trap messages enabled by the
command are sent to
any management station configured by the
command.
Example
The following example sets alarm thresholds for the transceiver temperature
at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold temperature low-alarm 97
Console(config-if)#transceiver-threshold temperature high-alarm -83
Console#
transceiver-threshold
tx-power
This command sets thresholds for the transceiver power level of the
transmitted signal which can be used to trigger an alarm or warning message.
Syntax
transceiver-threshold tx-power
{
high-alarm
|
high-warning
|
low-alarm
|
low-warning
}
threshold-value
high-alarm
– Sets the high power threshold for an alarm message.
high-warning
– Sets the high power threshold for a warning
message.
low-alarm
– Sets the low power threshold for an alarm message.
low-warning
– Sets the low power threshold for a warning
message.