  Hardened Managed PoE Ethernet Switch 

User’s Manual                                              182 

To restore 

to the default value, use the 

no ip igmp 

query-max-response-time

 command. 

 
3. 

Command Syntax: 

ip igmp query-max-response-time RESPONSETIME 
no ip igmp query-max-response-time 

RESPONSETIME <1-240> Maximum response time (in seconds) 
advertised in IGMP queries. Default: 10 seconds. 

 
4. 

Example: 

The following example configures a maximum response time of 8 seconds on 

vlan1.1

switch_a(config)#interface vlan1.1 
switch_a(config-if)#ip igmp query-max-response-time 8 
switch_a(config-if)# 

 

 

 
IGMP passive snooping: 
Static mc router port: 
1. 

Command Mode: Interface mode 

Logon to Configure Mode (Configure Terminal Mode). 
Then logon to Interface mode. 
vlan1.1 means vlan 1. 
The 

switch_a(config-if)#

 prompt will show on the screen. 

switch_a(config)#interface vlan1.1 
switch_a(config-if)# 

 
2. 

Usage: 

Use 

ip igmp snooping mrouter interface

  command to statically configure 

the specified VLAN constituent interface as a multicast router interface for 
IGMP Snooping in that VLAN. 
Use the 

no ip igmp snooping mrouter interface

 command to remove the 

static configuration of the interface as a multicast router interface. 
 
3. 

Command Syntax: 

(no) ip igmp snooping mrouter interface IFNAME 

IFNAME Specify the name of the interface 

 
4. 

Example: 

The following example shows interface fe1 (port 1) statically configured to be 
a multicast router interface on 

vlan1.1

switch_a(config)#interface vlan1.1 
switch_a(config-if)#ip igmp snooping mrouter interface fe1 
switch_a(config-if)# 

 

 

 

Summary of Contents for 065-7700

Page 1: ...Signamax Connectivity Systems Hardened Managed PoE Ethernet Switch Model 065 7700 U S E R S G U I D E ...

Page 2: ...Start Guide This quick start guide describes how to install and use the Hardened Managed PoE Power over Ethernet Ethernet Switch This is the switch of choice for harsh environments constrained by space Physical Description The Port Status LEDs and Power Inputs ...

Page 3: ...00BaseTX 100BaseFX BX SFP LINK ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY 10 100 1000BaseTX 1000BaseSX LX BX SFP LINK ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY Power Input Assignment Power3 47 57VDC DC Jack Power2 47 57VDC Terminal Block Power Ground Power1...

Page 4: ...5 Port 8 support IEEE802 3af Power over Ethernet PoE Power Sourcing Equipment PSE Supports IEEE802 3 802 3u 802 3ab 802 3z 802 3x Auto negotiation 1000Mbps full duplex 10 100Mbps full half duplex Auto MDI MDIX 100BaseFX Multi mode or Single mode duplex LC type 100BaseBX WDM Multi mode or Single mode single LC type 1000BaseSX LX Multi mode or Single mode duplex LC type 1000BaseBX WDM Multi mode or ...

Page 5: ...thernet Switch User s Manual 4 Industrial Control Equipment certified Maximum Surrounding Air Temperature 75 167 For use in Pollution Degree 2 Environment Hardened metal case Supports Din Rail or Panel Mounting installation ...

Page 6: ...ieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port Configuration settings of the terminal emulation program Baud rate 115 200bps Data bits 8 Parity none Stop bit 1 Flow control none Press the Enter key The Command Line Interface CLI screen should appear as below Logon to Exec Mode View Mode At the switch_a log...

Page 7: ...rminal Mode And the switch_a config prompt will show on the screen Set new IP address and subnet mask for Switch At the switch_a config prompt just type in interface vlan1 1 and press Enter to logon to vlan 1 vlan1 1 means vlan 1 And the switch_a config if prompt will show on the screen Command Syntax ip address A B C D M A B C D specifies IP address M specifies IP subnet mask M 8 255 0 0 0 16 255...

Page 8: ...Hardened Managed PoE Ethernet Switch User s Manual 7 Web Configuration Login the switch Specify the default IP address 192 168 1 10 of the switch in the web browser A login window will be shown as below ...

Page 9: ...Hardened Managed PoE Ethernet Switch User s Manual 8 Enter the factory default login ID root Enter the factory default password no password Then click on the Login button to log on to the switch ...

Page 10: ...Hardened Managed PoE Ethernet Switch User s Manual 9 ...

Page 11: ...oduced here is designed to deliver full scalability with SNMP RMON web based management functions by providing To get the most out of this manual you should have an understanding of Ethernet networking concepts In this manual you will find Features on the Hardened Managed PoE Ethernet Switch Illustrative LED functions Installation instructions Management Configuration SNMP IGMP Specifications ...

Page 12: ...18 SWITCH MANAGEMENT 19 Web based browser interface 19 Administration console via RS 232 serial port CLI 19 External SNMP based network management application 19 Installation 20 SELECTING A SITE FOR THE SWITCH 20 WIRING DIAGRAM 20 DIN RAIL MOUNTING 21 CONNECTING TO POWER 22 47 57VDC Jack 22 Redundant 47 57VDC DC Terminal Block Power Input 22 Alarms for Power Failure 23 CONNECTING TO YOUR NETWORK 2...

Page 13: ...CH 34 UNDERSTANDING THE BROWSER INTERFACE 36 SYSTEM 38 PORT 52 SWITCHING 58 TRUNKING 64 STP RING 65 VLAN 75 QOS 82 SNMP 85 802 1X 90 OTHER PROTOCOLS 94 Command Line Console Management 100 ADMINISTRATION CONSOLE 100 Exec Mode View Mode 101 Privileged Exec Mode Enable Mode 105 Configure Mode Configure Terminal Mode 110 SYSTEM 114 PORT 124 SWITCHING 129 TRUNKING 138 STP RING 139 VLAN 153 QOS 159 SNMP...

Page 14: ...ew Hardened Managed PoE Ethernet Switch Front View Package Contents When you unpack the product package you shall find the items listed below Please inspect the contents and report any apparent damage or missing items immediately to your authorized reseller This Switch ...

Page 15: ...Hardened Managed PoE Ethernet Switch User s Manual 14 User s Manual RS 232 cable ...

Page 16: ...ull duplex 10 100Mbps full half duplex Auto MDI MDIX 100BaseFX Multi mode or Single mode duplex LC type 100BaseBX WDM Multi mode or Single mode single LC type 1000BaseSX LX Multi mode or Single mode duplex LC type 1000BaseBX WDM Multi mode or Single mode single LC type Store and forward mechanism Full wire speed forwarding rate Alarms for power and port link failure by relay output Power Supply Re...

Page 17: ...ORING Port mirroring QOS IEEE802 1p Quality of Service 4 priority queues INTERNETWORKING PROTOCOLS Bridging IEEE802 1s Multiple Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1D Spanning Tree compatible IEEE802 1Q GVRP Ring IP Multicast IGMP Snooping Rate Control NTP NETWORK MANAGEMENT METHODS Console port access via RS 232 cable CLI Command Line Interface Telnet remote access SNMP agent MIB...

Page 18: ...s LEDs The LEDs are located on the front panel displaying status for each respective port Please refer to the following table for more details LED State Indication 10 100BaseTX LINK ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY PoE Steady Power Device PD is connected Off Power Device PD is disconnected ...

Page 19: ...rdened Managed Ethernet Switch provides Number of ports 10 100Base TX 802 3at 4 10 100Base TX 802 3af 0 4 100Base SFP 10 100Base TX 100Base FX BX 2 1000Base SFP 10 100 1000Base TX 1000Base SX LX BX 2 CONNECTIVITY RJ 45 connectors on TX ports Single or Duplex LC connectors on SFP 100BaseFX BX fiber transceiver Single or Duplex LC connectors on SFP 1000BaseSX LX BX fiber transceiver MODE SELECTION 1...

Page 20: ...t lets user access full switch configuration and functionality from a Netscape or Internet Explorer browser Administration console via RS 232 serial port CLI The switch provides an onboard serial port which allows the switch to be configured via a directly connected terminal External SNMP based network management application The switch can also be configured via SNMP ...

Page 21: ... Specifically the site you select should meet the following requirements The ambient temperature should be between 40 to 167 40 to 75 The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the switch receives adequate ventilation Do not block the ventilation holes on each side of th...

Page 22: ...to the back panel of the Media Converter Installation Place the Media Converter on the DIN rail from above using the slot Push the front of the Media Converter toward the mounting surface until it audibly snaps into place Removal Pull out the lower edge and then remove the Media Converter from the DIN rail ...

Page 23: ...eptacle on the topside of the switch Step 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage Redundant 47 57VDC DC Terminal Block Power Input Step 1 Connect the DC power cord to the plug able terminal block on the switch and then plug it into a standard DC outlet Step 2 Disconnect the power cord if you want to shut d...

Page 24: ...Power3 47 57VDC DC Jack Power2 47 57VDC Terminal Block Power Ground Power1 47 57VDC Power Ground Earth Ground Relay Output Rating 1A 250VAC Relay Alarm Assignment FAULT Warning signal disable for following 3 The relay contact closes if Power1 and Power2 are both failed but Power3 on 4 The relay contact closes if Power3 is failed but Power1 and Power2 are both on Special note The relay output is no...

Page 25: ...10BaseT RJ 45 10 20 Mbps 2 pair UTP STP Cat 3 4 5 100 m 100BaseTX RJ 45 100 200 Mbps 2 pair UTP STP Cat 5 100 m 1000BaseT RJ 45 2000 Mbps 4 pair UTP STP Cat 5 100 m 100BaseFX LC 200 Mbps MMF 50 62 5μm 2 km 100BaseFX LC 200 Mbps SMF 9 10μm 15 40 km 100BaseBX LC 200 Mbps MMF 50 62 5μm 2 km 100BaseBX LC 200 Mbps SMF 9 10μm 20 40 km 1000BaseSX LC 2000 Mbps MMF 62 5μm 275 m 2 km 1000BaseSX LC 2000 Mbps...

Page 26: ...Step 2 Prepare cable with corresponding connectors for each type of port in use Step 3 Consult Cable Specifications Table on previous page for cabling requirements based on connectors and speed Step 4 Connect one end of the cable to the switch and the other end to a desired device Step 5 Once the connections between two end devices are made successfully turn on the power and the switch is operatio...

Page 27: ...ystem It also contains information about port connection options This chapter covers the following topics Management Access Overview Key Concepts Key Guidelines for Implementation Web Management Access Administration Console Access SNMP Access Standards Protocols and Related Reading Management Access Overview The switch gives you the flexibility to access and manage the switch using any or all of ...

Page 28: ...irect Access Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port When using the management method configure the terminal emulation program to use the following parameters you can change these settings after login DEFAULT PARAMETERS 115 200bps 8 data bits No pari...

Page 29: ...y connected to the external modem Web Management The switch provides a browser interface that lets you configure and manage the switch remotely After you set up your IP address for the switch you can access the switch s web interface applications directly in your web browser by entering the IP address of the switch You can then use your web browser to list and manage switch configuration parameter...

Page 30: ...y to the console port SIMPLE NETWORK MANAGEMENT PROTOCOL SNMP SNMP is the standard management protocol for multivendor IP networks SNMP supports transaction based queries that allow the protocol to format messages and to transmit information between reporting devices and data collection programs SNMP runs on top of the User Datagram Protocol UDP offering a connectionless mode service Management Ar...

Page 31: ...ser Management The switch provides a web based browser interface for configuring and managing the switch This interface allows you to access the switch using a preferred web browser This chapter describes how to configure the switch using its web based browser interface ...

Page 32: ...ntelligent device or software agent that continually collects statistics about a LAN segment or VLAN The RMON probe transfers the collected data to a management workstation on request or when a pre defined threshold is reached The management workstation collects the statistics that the RMON probe gathers The workstation can reside on the same network as the probe or it can have an in band or out o...

Page 33: ...the following are met WARM START COLD START LINK UP LINK DOWN AUTHENTICATION FAILURE RISING ALARM FALLING ALARM TOPOLOGY ALARM MIB II defines a set of manageable objects in various layers of the TCP IP protocol suites MIB II covers all manageable objects from layer 1 to layer 4 and as a result is the major SNMP MIB supported by all vendors in the networking industry The switch supports a complete ...

Page 34: ...rms are triggered The action taken in the Network Management Station depends on the specific network management application Bridge Groups Supported The switch supports the following four groups of Bridge MIB RFC 1493 The dot1dBase Group a mandatory group that contains the objects applicable to all types of bridges The dot1dStp Group contains objects that denote the bridge s state with respect to t...

Page 35: ... configuring and managing the switch This interface allows you to access the switch using a preferred web browser This chapter describes how to configure the switch using its web based browser interface Logging on to the switch SWITCH IP ADDRESS In your web browser specify the IP address of the switch Default IP address is 192 168 1 10 ...

Page 36: ...nter the factory default login ID root PASSWORD Enter the factory default password no password Or enter a user defined password if you followed the instructions later and changed the factory default password Then click on the Login button to log on to the switch ...

Page 37: ...d of the screen for configuring and managing the switch SYSTEM System Information System Name Password IP Address ARP Table Route Table Save Configuration Firmware Upgrade Alarm Setting Reboot Logout PORT Configuration Port Status Rate Control RMON Statistics Per Port Vlan Activities SWITCHING Bridging Static MAC Entry Port Mirroring PoE PoE Scheduling TRUNKING Port Trunking ...

Page 38: ...TP Instance Setting MSTP Port Setting Recover Ring tm Capability VLAN VLAN Mode Setting 802 1Q VLAN Setting 802 1Q Port Setting Port Based VLAN QOS Global Configuration 802 1p Priority DSCP SNMP SNMP General Setting SNMP v1 v2c SNMP v3 802 1X Radius Configuration Port Authentication OTHER PROTOCOLS GVRP IGMP Snooping NTP ...

Page 39: ...ned Managed PoE Ethernet Switch User s Manual 38 System System Information The System name Firmware version System time MAC address Default gateway DNS Server VLAN ID IP Address and IP Subnet Mask of Switch ...

Page 40: ...place the current system name with a new one 2 Updating Setting Click Updating Setting button to update your settings 3 Password Click in Password text box Type a password 4 Retype Password Click in Retype Password text box Type the same password in Password text box again to verify it 5 Updating Setting Click Updating Setting button to update your settings ...

Page 41: ...r and reconnect to the switch after IP or subnet mask are changed 5 Default Gateway Click Default Gateway drop down menu to choose Disable or Enable from the Default Gateway drop down list to disable or enable Default Gateway Setting for the switch Click the text box and type a new address to change the Default Gateway Need to choose Enable from the Default Gateway drop down menu 6 Submit Click Su...

Page 42: ...S Server Setting for the switch Click the text box and type a new address to change the DNS Server Need to choose Enable from the DNS Server drop down menu 8 Submit Click Submit button when you finished DNS Server ARP Table Click ARP Table to view ARP Table ...

Page 43: ...Hardened Managed PoE Ethernet Switch User s Manual 42 Route Table Click Route Table to view Route Table ...

Page 44: ...backupped Click in FILE text box and type the name of the file that will be backupped Click Backup button to backup the file to the TFTP server 3 Save Configuration Click Save Configuration button to save your configuration settings 4 Restore Default Click Restore Default button to restore the default settings of the switch 5 Auto save Click Auto save drop down menu to choose Disable or Enable fro...

Page 45: ...server IP Click in TFTP server IP text box and type the TFTP server IP address from where the file will be obtained 3 Upgrade Click Upgrade button to upgrade firmware to the switch Please follow the message on the screen during the firmware upgrade process Do not turn off the power or perform other functions during this period of time Reboot the switch after completing the upgrade process ...

Page 46: ...ened Managed PoE Ethernet Switch User s Manual 45 Please follow the message on the screen during the firmware upgrade process Do not turn off the power or perform other functions during this period of time ...

Page 47: ...Hardened Managed PoE Ethernet Switch User s Manual 46 ...

Page 48: ...Hardened Managed PoE Ethernet Switch User s Manual 47 Firmware has been upgraded successfully to the switch Reboot the switch after completing the upgrade process ...

Page 49: ...Hardened Managed PoE Ethernet Switch User s Manual 48 ...

Page 50: ...enu to choose fe1 fe10 ge1 ge2 or Power1 Power3 from the Name drop down list 2 Trigger Enabled Click Trigger Enabled drop down menu to choose YES or NO from the Trigger Enabled drop down list to enable or disable Trigger 3 Update Setting Click Update Setting button to update settings to the switch ...

Page 51: ...Hardened Managed PoE Ethernet Switch User s Manual 50 Reboot Reboot Click Reboot button to restart the switch ...

Page 52: ...Hardened Managed PoE Ethernet Switch User s Manual 51 Logout Logout Click Logout button to logout of the switch ...

Page 53: ... to disable or enable Admin Setting for the port 2 Speed Click Speed drop down menu to change the line speed and duplex settings from the Speed drop down list for the port 3 Flow control Click Flow control drop down menu to choose Disable or Enable from the Flow control drop down list to disable or enable Flow control for the port 4 Submit Click Submit button when you finished configurations ...

Page 54: ...Hardened Managed PoE Ethernet Switch User s Manual 53 ...

Page 55: ...the Detected Connector Transceiver Mode Wave Length nm Link Length m Temperature C Vcc V Tx_bias mA Tx_pow dbm and Rx_pow dbm information for SFP ports 2 Alarm Situation View Current Temperature Alarm Current VCC Alarm Current Tx Bias Alarm Current Tx Power Alarm and Current Rx Power Alarm 3 Alarm Setting Click in Threshold Value text boxes and type new ...

Page 56: ...Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Rate Control 1 Ingress Click in Ingress text box and type a new Rate to change the Ingress Rate Control for the port Rate Values 64kbps 128kbps 192kbps 1792kbps 2Mbps 3Mbps 4Mbps 100Mbps 104Mbps 112Mbps 120Mbps 1000Mbps Note M 1024k 2 Egress Click in Egress text box and type a ...

Page 57: ...itch User s Manual 56 104Mbps 112Mbps 120Mbps 1000Mbps Note M 1024k 3 Update Setting Click Update Setting button when you finished these Rate Control settings RMON Statistics Click Port 1 Port 12 to view corresponding RMON Statistics ...

Page 58: ...Hardened Managed PoE Ethernet Switch User s Manual 57 Per Port Vlan Activities Click Port 1 Port 12 to view corresponding vlan activities ...

Page 59: ...g Click Update Setting button when you finished Aging Time settings 3 Threshold level 0 1 100 Click in Level text box and type a decimal number for the port Need to choose Broadcast and or DFL Multicast from Storm control enabled type for the port DLF Destination Lookup Failure 4 Storm control enabled type Choose Broadcast and or DLF Multicast from Storm control enabled type for the port ...

Page 60: ...C address for the port 2 VLAN ID Click VLAN ID drop down menu and choose a VLAN ID from the VLAN ID drop down list 3 Delete MAC address Click Delete MAC address drop down menu and choose a locked forwarding MAC address from the Delete MAC address drop down list to be deleted from the port 4 Submit Click Submit button when you finished Static MAC Entry Forward settings Static MAC Entry Discard 1 Ad...

Page 61: ...rom the Delete MAC address drop down list to be discarded from the VLAN 4 Submit Click Submit button when you finished Static MAC Entry Discard settings Port Mirroring 1 Mirror From Choose Mirror From port from Port 1 Port 12 2 Mirror To Click Mirror To drop down menu to Choose Mirror To port Port 1 Port 12 from Mirror To drop down list 3 Mirror Mode Click Mirror Mode drop down menu to Choose Tx R...

Page 62: ... PoE Port Setting 1 Enable Mode Click Enable Mode drop down menu to choose Disable Enable or Scheduling from Enable Mode drop down list to disable enable or schedule this port to discover Powered Device PD connected to this port 2 Fixed Power Limit W Click in Fixed Power Limit W text box and type a new fixed power limit for this port to provide power to PD 3 Power Priority Click Power Priority dro...

Page 63: ...n Switching from main menu Then click on PoE from Switching In PoE Port Setting click Enable Mode drop down menu to choose Scheduling from Enable Mode drop down list to schedule this port to discover Powered Device PD connected to this port PoE Per Port Scheduling 1 Port Click Port drop down menu to choose a port from Port drop down list and configure PoE scheduling to this port 2 Submit Click Sub...

Page 64: ...Hardened Managed PoE Ethernet Switch User s Manual 63 port ...

Page 65: ... Static Channel Group 1 Trunk 1 Click Port 1 Port 10 to assign ports to Trunk 1 Maximum 4 ports per Trunk GE Trunking 1 Trunk 3 Check Static or Disable to enable or disable Trunk 3 for Gigabit Ethernet ports 2 Submit Click Submit button when you finished Port Trunking settings ...

Page 66: ...drop down list to enable or disable Spanning Tree Protocol 2 Bridge Priority 0 61440 Click in Bridge Priority text box and type a decimal number between 0 and 61440 3 Hello Time sec 1 9 Click in Hello Time text box and type a decimal number between 1 and 9 4 Max Age sec 6 28 Click in Max Age text box and type a decimal number between 6 and 28 5 Forward Delay sec 4 30 Click in Forward Delay text bo...

Page 67: ...o set the priority for the port A higher priority will designate the port to forward packets first A lower number denotes a higher priority This entry must be divisible by 16 The default priority setting is 128 4 Admin Path Cost Click in Admin Path Cost text box and enter a value between 0 and 2000000 to set the Admin Path Cost for the port 0 auto Setting 0 for the Admin Path Cost will automatical...

Page 68: ... PoE Ethernet Switch User s Manual 67 Disable or Auto from Edge Port drop down list to set Enable Disable or Auto Edge Port for the port 7 Update Setting Click Update Setting button when you finished RSTP Port Setting ...

Page 69: ...e is a region by itself unless specifically added to one 3 Revision Level Click in Revision Level text box to specify the number for configuration information The default value of revision number is 0 4 Max Hops Click in Max Hops text box to specify the maximum allowed hops for BPDU in an MST region This parameter is used by all the instances of the MST Specifying the max hops for a BPDU prevents ...

Page 70: ...Hardened Managed PoE Ethernet Switch User s Manual 69 ...

Page 71: ...D text box to specify the instance ID 4 Update Setting Click Update Setting button when you finished VLAN Instance Configuration Included VLANs 1 Instance ID Click Instance ID drop down menu to choose instance ID from Instance ID drop down list 2 Included VLAN Click Included VLAN drop down menu to choose VLAN from Included VLAN drop down list Instance Setting 1 Bridge Priority 0 61440 Click in Bri...

Page 72: ...Hardened Managed PoE Ethernet Switch User s Manual 71 2 Update Setting Click Update Setting button when you finished VLAN Instance Configuration ...

Page 73: ...tance ID 1 Instance ID Click Instance ID drop down menu to choose instance ID from Instance ID drop down list MSTP Port Configuration 1 Port Click Port drop down menu to choose port from Port drop down list 2 Priority Granularity 16 Click in Priority text box to set the port priority for a bridge group The Multiple Spanning Tree Protocol uses port priority as a tiebreaker to determine which port s...

Page 74: ...th an interface 4 Update Setting Click Update Setting button when you finished MSTP Port Setting Recover Ring tm Capability Ring state 1 Click Ring state drop down menu from Ring state drop down list to choose Enable or Disable to enable or disable Ring state 2 Update Setting Click Update Setting button when you finished Ring state setting Set ring port 1 Ring port 1 Click Ring port 1 drop down me...

Page 75: ...Hardened Managed PoE Ethernet Switch User s Manual 74 3 Update Setting Click Update Setting button when you finished Set ring port ...

Page 76: ...r s Manual 75 VLAN VLAN Mode Setting 1 VLAN Mode Setting Click VLAN Mode Setting drop down menu to Choose Tag based VLAN or Port based VLAN from VLAN Mode Setting drop down list 2 Submit Click Submit button when you finished VLAN Mode Setting ...

Page 77: ...Hardened Managed PoE Ethernet Switch User s Manual 76 ...

Page 78: ...4094 Click in the VLAN ID textbox and specify a new VLAN ID number from 2 4094 4 VLAN Name Click in the VLAN Name textbox and type a name for this newly created VLAN Add port to or delete port from VLAN 1 VLAN Member Choose the port to be added to or deleted from the VLAN 2 Tag or Untag Click Tag or Untag drop down menu to Choose Tag or Untag from Tag or Untag drop down list for a Hybrid port 3 Su...

Page 79: ...ng Click 802 1Q VLAN Setting The VLAN Setting window appears 2 Delete VLAN Click Delete VLAN button 3 Select a VLAN ID Click Select a VLAN ID drop down menu from Select a VLAN ID drop down list to choose the VLAN to be deleted 4 Submit Click Submit button when you finished VLAN setting ...

Page 80: ...p down menu to Choose Access Trunk or Hybrid from Mode drop down list for the port The port will be Tag port if you choose Trunk Mode for the port And the port will be Tag or Untag port if you choose Hybrid Mode for the port 3 PVID Click in the PVID textbox and specify a new PVID number for the port 4 Update Setting Click Update Setting button when you finished VLAN Port Setting ...

Page 81: ...Hardened Managed PoE Ethernet Switch User s Manual 80 Port Based VLAN 1 VLAN Choose the port to be added to or deleted from the VLAN ...

Page 82: ... 2 Select all Click select all button to choose Port 1 Port 12 all to be added to the VLAN 3 Delete all Click delete all button to choose Port 1 Port 12 all to be deleted from the VLAN 4 Submit Click Submit button when you finished Port Based VLAN setting ...

Page 83: ...d port to trust the DSCP Differentiated Service Code Point labels of all traffic received on that port 3 Policy Choose Strict Priority Queue3 WRR Queue0 2 or WRR Queue0 3 A strict priority queue is always emptied first The queues that are used in the WRR Weighted Round Robin are emptied in a round robin fashion and you can configure the weight for each queue 4 Weighted Round Robin Click in the Wei...

Page 84: ...oE Ethernet Switch User s Manual 83 802 1p Priority 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for VLAN Priority 0 7 2 Submit Click Submit button when you finished 802 1p priority ...

Page 85: ... Managed PoE Ethernet Switch User s Manual 84 DSCP 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for DSCP Priority 0 63 2 Submit Click Submit button when you finished DSCP ...

Page 86: ... menu from SNMP Status drop down list to choose Enable or Disable to enable or disable SNMP 2 Description Click in the Description textbox and specify a new description for SNMP 3 Location Click in the Location textbox and specify a new location for SNMP 4 Contact Click in the Contact textbox and specify a new contact for ...

Page 87: ...drop down list to choose Enable or Disable to enable or disable link down trap 8 Link Up Trap Click Link Up Trap drop down menu from Link Up Trap drop down list to choose Enable or Disable to enable or disable link up trap 9 Update Setting Click Update Setting button when you finished SNMP General Setting SNMP v1 v2c 1 Get Community Name Click in the Get Community Name textbox and specify a get co...

Page 88: ...Hardened Managed PoE Ethernet Switch User s Manual 87 ...

Page 89: ... with authentication Click in the Auth Password textbox and specify an authentication password SNMPv3 Auth SHA Add a user using SNMP v3 with authentication Click in the Auth Password textbox and specify an authentication password SNMPv3 Priv Auth MD5 Add a user using SNMP v3 with authentication and privacy Click in the Auth Password textbox and specify an authentication password Click in the Priva...

Page 90: ...or Read Write Read Only Add a user using SNMP v3 with read only access mode Read Write Add an user using SNMP v3 with read write access mode 5 Submit Click Submit button when you finished SNMP V3 Setting Delete User 1 Delete User Click Delete User button The Select User Name window appears 2 Select User Name Click Select User Name drop down menu from Select User Name drop down list to choose the u...

Page 91: ...Radius Configuration 1 Radius Status Click Radius Status drop down menu from Radius Status drop down list to choose Enable or Disable to globally enable or disable authentication 2 Update Setting Click Update Setting button when you finished Radius Status Setting ...

Page 92: ...witch and radius server This key must match the encryption used on the radius daemon All leading spaces are ignored but spaces within and at the end of the key are used If spaces are used in the key do not enclose the key in quotaion marks unless the quotation marks themselves are part of the key 5 Timeout 1 1000 Click in the Timeout textbox and specify the time interval in seconds that the Switch...

Page 93: ...button The Select Radius Server IP window appears 2 Select Radius Server IP Click Select Radius Server IP drop down menu from Select Radius Server IP drop down list to choose the IP address of the remote radius server host to be deleted 3 Submit Click Submit button when you finished radius server deletion ...

Page 94: ...thorized to force a port state Auto specifies to enable authentication on port Force Authorized specifies to force a port to always be in an authorized state Force Unauthorized specifies to force a port to always be in an unauthorized state 4 Periodic Reauthentication Click Periodic Reauthentication drop down menu from Periodic Reauthentication drop down list to choose Enable or Disable to enable ...

Page 95: ...d Managed PoE Ethernet Switch User s Manual 94 Other Protocols GVRP GVRP Global Setting 1 GVRP Click GVRP drop down menu from GVRP drop down list to choose Enable or Disable to enable or disable GVRP GARP VLAN ...

Page 96: ...VRP applicant drop down menu from GVRP applicant drop down list to choose Active or Normal to the port Ports in the GVRP active applicant state send GVRP VLAN declarations when they are in the STP Spanning Tree Protocol blocking state which prevents the STP bridge protocol data units BPDUs from being pruned from the other port Ports in the GVRP normal applicant state do not declare GVRP VLANs when...

Page 97: ...ID drop down menu from VLAN ID drop down list to choose the VLAN under configuration for the switch 4 IGMP version Click IGMP version drop down menu from IGMP version drop down list to choose 1 2 or 3 for the switch 5 Fast leave Click fast leave drop down menu from fast leave drop down list to choose Enable or Disable for the switch Enable this function will allow members of a multicast group to l...

Page 98: ...r the switch Use this command to enable report suppression for IGMP version 1 and version 2 Report suppression does not apply to IGMP version 3 and is turned off by default for IGMP version 1 and IGMP version 2 reports The switch uses IGMP report suppression to forward only one IGMP report per multicast router query to multicast devices When IGMP router suppression is enabled the switch sends the ...

Page 99: ...on when you finished Adjust RTC Time NTP Setting 1 NTP Status Click NTP Status drop down menu from NTP Status drop down list to choose Enable or Disable to enable or disable NTP for the Switch 2 NTP Server IP Address or Domain name Click in the NTP Server textbox and specify the IP address or Domain name of NTP server 3 Sync Time Click Sync Time button to synchronize time with NTP server ...

Page 100: ...ls Enter the name of Daylight Saving time zone using the following example EDT East Daylight Saving Time Zone CDT Central Daylight Saving Time Zone MDT Mountain Daylight Saving Time Zone PDT Pacific Daylight Saving Time Zone ADT Alaska Daylight Saving Time Zone 4 Weekday Specify the daylight saving period Month Click Month drop down menu from Month drop down list to choose from January to December...

Page 101: ...y Commend Line Administration Console Connect the DB9 straight cable to the RS 232 serial port of the device to the RS 232 serial port of the terminal or computer running the terminal emulation application Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port When...

Page 102: ...anaged PoE Ethernet Switch User s Manual 101 Exec Mode View Mode Logon to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon to Exec Mode or View Mode switch_a login root ...

Page 103: ... help facility Access this help by typing in the full or partial command string then typing a question mark The CLI displays the command keywords or parameters along with a short description At the switch_a prompt just press to list the above basic commands switch_a At the switch_a prompt just type in the full or partial command string then typing a question mark to display the command keywords or...

Page 104: ...Login timed out The login session to Exec Mode or View Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View Mode ...

Page 105: ...t the switch_a login prompt just type in root and press Enter to logon back to Exec Mode or View Mode switch_a login root Exit from Exec Mode View Mode At the switch_a prompt just type in exit and press Enter to exit from Exec Mode or View Mode switch_a exit ...

Page 106: ...l 105 Privileged Exec Mode Enable Mode Logon to Privileged Exec Mode Enable Mode At the switch_a prompt just type in enable and press Enter to logon to Privileged Exec Mode or Enable Mode And the switch_a prompt will show on the screen switch_a enable ...

Page 107: ...rdened Managed PoE Ethernet Switch User s Manual 106 Commands Privileged Exec Mode or Enable Mode allows users to run commands as following At the switch_a prompt just press to list the commands switch_a ...

Page 108: ...Ethernet Switch User s Manual 107 At the switch_a prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch_a show ...

Page 109: ...Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon back to Exec Mode or View Mode switch_a login root ...

Page 110: ...Managed PoE Ethernet Switch User s Manual 109 Exit from Privileged Exec Mode or Enable Mode At the switch_a prompt just type in exit and press Enter to exit from Privileged Exec Mode or Enable Mode switch_a exit ...

Page 111: ...pt just type in configure terminal and press Enter to logon to Configure Mode or Configure Terminal Mode And the switch_a config prompt will show on the screen switch_a configure terminal Commands Configure Mode or Configure Terminal Mode serves as a gateway into the modes as following At the switch_a config prompt just press to list the commands switch_a config ...

Page 112: ...t Switch User s Manual 111 At the switch_a config prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch_a config show ...

Page 113: ...al Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon back to Exec Mode or View Mode switch_a login root ...

Page 114: ...thernet Switch User s Manual 113 Exit from Configure Mode or Configure Terminal Mode At the switch_a config prompt just type in exit and press Enter to exit from Configure Mode or Configure Terminal Mode switch_a config exit ...

Page 115: ... disable this function 3 Command Syntax no hostname HOSTNAME HOSTNAME specifies the network name of the system 4 Example The following example sets the hostname to switch and shows the change in the prompt switch_a config hostname switch switch config Password 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a c...

Page 116: ...x ip address IP ADDRESS no ip address IP ADDRESS no ip address IP ADDRESS A B C D M specifies the IP address and prefix length of an interface M specifies IP subnet mask 8 255 0 0 0 16 255 255 0 0 24 255 255 255 0 4 Example The following example sets the new IP address 192 168 1 10 and new IP subnet mask 255 255 255 0 to switch switch_a config interface vlan1 1 switch_a config if ip address 192 16...

Page 117: ..._a config prompt will show on the screen switch_a config 2 Usage Use ip dns command to set the IP address of the DNS server Use the no ip dns command to remove the IP address of the DNS server 3 Command Syntax ip dns IP ADDRESS no ip dns IP ADDRESS A B C D specifies the IP address of the DNS server 4 Example The following example sets the DNS server 192 168 1 100 to switch switch_a config ip dns 1...

Page 118: ...itch switch_a show route table Save Configuration Load config from TFTP server 1 Command Mode Privileged Exec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use install image command to load configuration file from tftp server to switch 3 Command Syntax install image IP ADDRESS WORD IP ADDRESS specifies the IP address of tftp server WORD...

Page 119: ...e config file 192 168 1 20 switch_a Save Configuration 1 Command Mode Privileged Exec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use copy running config startup config command to write configurations to the file to be used at startup This is the same as the write memory command 3 Command Syntax copy running config startup config 4 Ex...

Page 120: ...ed at every configured interval while this command is enabled Use the no form of this command to disable this feature 3 Command Syntax service auto config enable no service auto config enable 4 Example The following example enables or disables auto save configuration to switch switch_a config service auto config enable switch_a config no service auto config enable switch_a config Auto Save Interva...

Page 121: ...witch_a prompt will show on the screen switch_a 2 Usage Use install image command to upgrade firmware from tftp server to switch 3 Command Syntax install image IP ADDRESS WORD IP ADDRESS specifies the IP address of tftp server WORD specifies the file name to be upgraded to switch 4 Example The following example specifies upgrading firmware file name flash tgz from tftp server IP address 192 168 1 ...

Page 122: ...Hardened Managed PoE Ethernet Switch User s Manual 121 At the switch_a prompt just type in reload and press Enter to reboot the switch after completing the upgrade process ...

Page 123: ...to switch switch_a config alarm trigger if fe1 switch_a config Alarm trigger power 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to enable or disable alarm trigger of power source 3 Command Syntax no alarm trigger power POWER POWER specifies the power source 4 Example The fol...

Page 124: ... 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a switch_a 2 Usage Use logout command to exit from the Exec mode or Privileged Exec mode 3 Command Syntax logout 4 Example The following example specifies to exit from the Exec mode or Privileged Exec mode switch_a logout ...

Page 125: ...e no shutdown to disable this function 3 Command Syntax no shutdown 4 Example The following example shows the use of the shutdown command to shut down the interface fe1 port 1 switch_a config interface fe1 switch_a config if shutdown switch_a config if Bandwidth 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a ...

Page 126: ...Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use duplex command to specify the duplex mode to be used for each interface Use the no duplex to disable this function 3 Command Syntax no duplex MODE MODE specifies the duplex mode auto full half 4 Examp...

Page 127: ...e fe1 port 1 switch_a config interface fe1 switch_a config if flowcontrol on switch_a config if Port Status 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a switch_a 2 Usage Use the show interface command to display interface configuration and status 3 Command Syntax sh...

Page 128: ...ss egress VALUE VALUE 1 10000000000 bits usable units k m g 1 999 k m for 1 to 999 kilo bits or mega bits 1g for 1 giga bits 4 Example The following example shows the use of rate control ingress VALUE 10 mega bits to the interface fe1 port 1 switch_a config interface fe1 switch_a config if rate control ingress 10m switch_a config if RMON Statistics 1 Command Mode Exec mode or Privileged Exec mode ...

Page 129: ...Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a switch_a 2 Usage Use show vlan command to display information about a particular VLAN by specifying the VLAN ID 3 Command Syntax show vlan 2 4094 2 4094 VLAN ID 4 Example The following is an output of show vlan command disp...

Page 130: ...bridge group that this ageing time is for AGEINGTIME 10 1000000 The number of seconds of persistence 4 Example The following example sets the new AGEINGTIME 1000 to bridge GROUP 1 switch_a config bridge 1 ageing time 1000 switch_a config Threshold level 0 100 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a con...

Page 131: ...n the screen switch_a config interface fe1 switch_a config if 2 Usage Use storm control broadcast enable command to enable broadcast traffic Use no storm control broadcast command to disable broadcast traffic 3 Command Syntax storm control broadcast enable no storm control broadcast 4 Example The following example shows setting storm control broadcast enable to the interface fe1 port 1 switch_a co...

Page 132: ...o Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use storm control dlf enable command to enable destination lookup failure traffic Use no storm control dlf command to disable destination lookup failure traffic 3 Command Syntax storm control dlf enable...

Page 133: ...ROUP 1 to forward matching frames MAC address 2222 2222 2222 to the interface fe1 port 1 in vlan VLANID 2 switch_a config bridge 1 address 2222 2222 2222 forward fe1 vlan 2 switch_a config Static MAC Entry Discard 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to statically co...

Page 134: ...URCEPORT direction SNOOPDIRECTION no mirror interface SOURCEPORT SOURCEPORT Name of the Source interface to be used SNOOPDIRECTION both receive transmit both Specifies mirroring of traffic in both directions receive Specifies mirroring of received traffic transmit Specifies mirroring of transmitted traffic 4 Example The following example enables port mirroring by the destination port fe1 port 1 on...

Page 135: ...itch_a config if 2 Usage Use poe enable command to enable this port to discover Powered Device PD connected to this port Use the no poe enable to disable this function 3 Command Syntax no poe enable 4 Example The following example shows the use of poe enable to the interface fe1 port 1 switch_a config interface fe1 switch_a config if poe enable switch_a config if Fixed Power Limit W 1 Command Mode...

Page 136: ...s port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to specify the power priority to this port 3 Command Syntax poe power priority PRIORITY PRIORITY specifies high medium low power priority for this port 4 Example The following example sets high power priority to the interface fe1 port 1 switch_a config interface ...

Page 137: ... Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to enble PoE scheduling to this port 3 Command Syntax poe schedule enable 4 Example The following example enables PoE scheduling to the interface fe1 port 1 switc...

Page 138: ... this port 3 Command Syntax poe schedule time DAY HOUR DAY 0 6 specifies Sunday Saturday to Switch HOUR 0 23 specifies hours to Switch no poe schedule time 4 Example The following example sets PoE scheduling to the interface fe1 port 1 switch_a config interface fe1 switch_a config if poe schedule time 0 0 switch_a config if ...

Page 139: ... to create a static aggregator or add a member port to an already existing static aggregator Use the no static channel group command to detach the port from the static aggregator 3 Command Syntax static channel group 1 3 no static channel group 1 3 Channel group number Maximum 4 ports in static channel group 1 and static channel group 2 Maximum 2 ports in static channel group 3 4 Example The follo...

Page 140: ...lan bridge GROUP 1 1 Bridge group name used for bridging PROTOCOL ieee IEEE 802 1Q spanning tree protocol mstp IEEE 802 1s multiple spanning tree protocol rstp IEEE 802 1w rapid spanning tree protocol 4 Example The following example chooses the PROTOCOL rstp on bridge GROUP 1 switch_a config bridge 1 protocol rstp vlan bridge switch_a config Multiple Spanning Tree Protocol 1 Command Mode Configure...

Page 141: ...creen switch_a config 2 Usage Use this command to enable the Rapid Spanning Tree protocol on a bridge Use the no form of the command to disable the Rapid Spanning Tree protocol on a bridge 3 Command Syntax bridge GROUP rapid spanning tree enable no bridge GROUP rapid spanning tree enable BRIDGE FORWARD GROUP 1 1 Bridge group name used for bridging BRIDGE FORWARD Puts all ports of the specified bri...

Page 142: ...bridge forward switch_a config Bridge Priority 0 61440 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set bridge priority for the common instance Using a lower priority indicates a greater likelihood of the bridge becoming root 3 Command Syntax bridge GROUP priority PRIORIT...

Page 143: ...E 9 of bridge GROUP 1 switch_a config bridge 1 hello time 9 switch_a config Max Age sec 6 28 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set the max age for a bridge Use the no parameter with this command to restore the default value of max age 3 Command Syntax bridge GR...

Page 144: ...0 the forwarding time delay in seconds 4 Example The following example sets the forward time FORWARD_DELAY 30 of bridge GROUP 1 switch_a config bridge 1 forward time 30 switch_a config RSTP Port Setting Priority Granularity 16 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the sc...

Page 145: ...st of a path associated with a bridge group 3 Command Syntax bridge GROUP path cost PATHCOST no bridge GROUP path cost GROUP 1 1 the ID of the bridge group PATHCOST 1 200000000 The cost to be assigned to the group 4 Example The following example sets the cost 123 of the interface fe1 port 1 of bridge GROUP 1 switch_a config interface fe1 switch_a config if bridge 1 path cost 123 switch_a config if...

Page 146: ...if Autoedge 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use spanning tree autoedge command to assist in automatic identification of the edge port Use the no spanning tree autoedge command to disable this featu...

Page 147: ...P Properties Region Name 1 Command Mode MST Configuration mode Logon to Configure Mode Configure Terminal Mode Then logon to MST Configuration mode The switch_a config mst prompt will show on the screen switch_a config spanning tree mst configuration switch_a config mst 2 Usage Use this command to create an MST region and specify a name to it MST bridges of a region form different spanning trees f...

Page 148: ... bridge group ID REVISION_NUM 0 255 Revision number 4 Example The following example specifies a revision number 25 of MST configuration in bridge GROUP 1 switch_a config spanning tree mst configuration switch_a config mst bridge 1 revision 25 switch_a config mst Max Hops 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen...

Page 149: ...the corresponding instance of a bridge This command can be used only after the VLANs are defined Use the no parameter with this command to simultaneously remove multiple VLANs for the corresponding instance of a bridge 3 Command Syntax bridge GROUP instance INSTANCE_ID vlan VLAN_ID no bridge GROUP instance INSTANCE_ID vlan VLAN_ID GROUP 1 1 Specify the bridge group ID INSTANCE_ID 1 15 Specify the ...

Page 150: ...ID BRIDGE_PRIORITY 0 61440 Specify the bridge priority 4 Example The following example sets the bridge priority 0 for an MST instance 3 in bridge GROUP 1 switch_a config bridge 1 instance 3 priority 0 switch_a config MSTP Port Setting Bridge Group Instance 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config...

Page 151: ...he case of the same priority the interface index will serve as the tiebreaker with the lower numbered interface being preferred over others The permitted range is 0 240 The priority values can only be set in increments of 16 3 Command Syntax bridge GROUP instance INSTANCE_ID priority PRIORITY GROUP 1 1 Specify the bridge group ID INSTANCE_ID 1 15 Specify the instance ID PRIORITY 0 240 Specify the ...

Page 152: ...r Multiple Spanning Tree instance 3 to a port fe1 in bridge GROUP 1 switch_a config interface fe1 switch_a config if bridge group 1 instance 3 path cost 1000 switch_a config if Recover Ring tm Capability Ring state 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to enable Ring ...

Page 153: ...rompt will show on the screen switch_a config 2 Usage Use this command to set Ring port 1 and Ring port 2 3 Command Syntax ring set port RING_PORT_1 RING_PORT_2 RING_PORT_1 Specify the Ring port 1 RING_PORT_2 Specify the Ring port 2 4 Example The following example sets the fe1 and fe2 as Ring port 1 and Ring port 2 switch_a config ring set port fe1 fe2 switch_a config ...

Page 154: ...tch_a config vlan Add VLAN Delete VLAN 1 Command Mode VLAN Configure mode Logon to Configure Mode Configure Terminal Mode Logon to VLAN Configure Mode The switch_a config vlan prompt will show on the screen switch_a config vlan database switch_a config vlan 2 Usage This command enables or disables the state of a particular VLAN on a bridge basis Specifying the disable state causes all forwarding o...

Page 155: ... Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use switchport mode access command to set the switching characteristics of the Layer 2 interface to access mode and classify untagged frames only Use the no switchport access command to reset the mode of the Layer 2 interface to access defaul...

Page 156: ... be received 4 Example The following example sets the switchport mode hybrid of the interface fe1 port 1 and all frames to be received on interface fe1 port 1 switch_a config interface fe1 switch_a config if switchport mode hybrid acceptable frame type all switch_a config if Switchport mode trunk 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface ...

Page 157: ...rid allowed vlan add VLANID egress tagged enable disable switchport hybrid allowed vlan remove VLANID no switchport hybrid vlan all Allow all VLANs to transmit and receive through the Layer 2 interface none Allow no VLANs to transmit and receive through the Layer 2 interface add Add a VLAN to the member set remove Remove a VLAN from the member set VLANID 2 4094 The ID of the VLAN or VLANs that wil...

Page 158: ...nk allowed vlan add VLANID switchport trunk allowed vlan remove VLANID switchport trunk allowed vlan except VLANID no switchport trunk vlan all Allow all VLANs to transmit and receive through the Layer 2 interface none Allow no VLANs to transmit and receive through the Layer 2 interface add Add a VLAN to transmit and receive through the Layer 2 interface remove Remove a VLAN from transmit and rece...

Page 159: ...how on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set or remove the default VLAN for the interface 3 Command Syntax switchport portbase add remove vlan VLANID VLANID The ID of the VLAN will be added to or removed from the Layer 2 interface 4 Example The following example specifies to add the interface fe1 port 1 to VLANID 2 switch_a config interface fe1...

Page 160: ...s 4 Example The following example globally enables QoS on the switch switch_a config mls qos enable switch_a config Trust 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use mls qos trust command to turn on QoS trust CoS or DSCP Use the no mls qos trust command to turn off QoS trust CoS or DSCP...

Page 161: ...gress expedite queue on the switch switch_a config priority queue out switch_a config Weighted Round Robin 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use wrr queue bandwidth command to specify the bandwidth ratios of the transmit queues 3 Command Syntax wrr queue bandwidth WRR_WTS WRR_WTS ...

Page 162: ...ample shows mapping CoS values 0 and 1 to queue 1 on the switch switch_a config wrr queue cos map 1 0 1 switch_a config DSCP 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use mls qos map dscp queue command to map the DSCP values to a queue 3 Command Syntax mls qos map dscp queue DSCP_VALUE to...

Page 163: ... The following example enables SNMP to the switch switch_a config snmp server enable switch_a config Description 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server description command to specify and no snmp server description command to remove description for SNMP 3 Command Syntax ...

Page 164: ...ple The following example specifies location location for SNMP switch_a config snmp server location location switch_a config Contact 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server contact command to specify and no snmp server contact command to remove contact for SNMP 3 Command...

Page 165: ... 1 name for SNMP switch_a config snmp server trap community 1 name switch_a config Trap Host IP Address 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify trap host IP address for SNMP Use the no parameter with this command to remove trap host IP address for SNMP 3 Comm...

Page 166: ...p for SNMP switch_a config snmp server trap type enable coldStart switch_a config Warm Start Trap 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server trap type enable warmStart command to enable warm start trap for SNMP Use the no snmp server trap type enable warmStart command to di...

Page 167: ...Link Up Trap 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server trap type enable linkUp command to enable link up trap for SNMP Use the no snmp server trap type enable linkUp command to disable link up trap for SNMP 3 Command Syntax no snmp server trap type enable linkUp 4 Example ...

Page 168: ...nal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server trap type enable topologyChange command to enable topology change trap for SNMP Use the no snmp server trap type enable topologyChange command to disable topology change trap for SNMP 3 Command Syntax no snmp server trap type enable topologyChange 4 Example The following example enables topology cha...

Page 169: ...mmunity set command to specify and no snmp server community set command to remove set community name for SNMP 3 Command Syntax snmp server community set NAME no snmp server community set NAME The set community name for SNMP 4 Example The following example specifies set community name name for SNMP switch_a config snmp server community set name switch_a config SNMP v3 SNMPv3 No Auth 1 Command Mode ...

Page 170: ...v3 with read only or read write access mode and with MD5 or SHA authentication Use the no form of the command to delete this user 3 Command Syntax no snmp server v3 user USERNAME ro rw auth md5 sha AUTH_PASSWORD USERNAME Specify a user name ro read only access mode rw read write access mode md5 authentication method sha authentication method AUTH_PASSWORD authentication password 4 Example The foll...

Page 171: ...SSWORD des PRIV_PASS_PHRASE USERNAME Specify a user name ro read only access mode rw read write access mode md5 authentication method sha authentication method AUTH_PASSWORD authentication password PRIV_PASS_PHRASE encryption pass phrase 4 Example The following example adds a user myuser using snmp v3 with read write access mode MD5 authentication mypassword and encryption pass phrase mypassphrase...

Page 172: ...system auth ctrl switch_a config Radius Server IP Radius Server Port 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify the IP address of the remote radius server host and assign authentication and accounting destination port number 3 Command Syntax no radius server hos...

Page 173: ... server and the 802 1x client 4 Example The following example specifies the IP address 192 168 1 100 of the remote radius server host and set the secret key ipi shared among the radius server and the 802 1x client switch_a config radius server host 192 168 1 100 key ipi switch_a config Timeout 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt ...

Page 174: ...ius server retransmit RETRIES no radius server retransmit RETRIES 1 100 Specifies the retransmit value Enter a value in the range 1 to 100 4 Example The following example specifies the retransmit value 12 switch_a config radius server retransmit 12 switch_a config Port Authentication Authentication State 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to In...

Page 175: ...ort from the 802 1x management 3 Command Syntax dot1x port control auto force authorized force unauthorized no dot1x port control auto Specify to enable authentication on port force authorized Specify to force a port to always be in an authorized state force unauthorized Specify to force a port to always be in an unauthorized state 4 Example The following example specifies to enable authetication ...

Page 176: ...etween reauthorization attempts 3 Command Syntax dot1x timeout re authperiod SECS no dot1x timeout re authperiod SECS 1 4294967295 Specify the seconds between reauthorization attempts The default time is 3600 seconds 4 Example The following example specifies to set the interval 25 seconds between reauthorization attempts switch_a config interface fe1 switch_a config if dot1x timeout re authperiod ...

Page 177: ...bridge 3 Command Syntax set gvrp enable bridge GROUP set gvrp disable bridge GROUP GROUP Bridge group ID used for bridging 4 Example The following example globally enables GVRP to bridge GROUP 1 switch_a config set gvrp enable bridge 1 switch_a config Dynamic VLAN creation 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the scre...

Page 178: ...l ports in a bridge 3 Command Syntax set port gvrp enable all IFNAME set port gvrp disable all IFNAME all All ports added to recently configured bridge IFNAME The name of the interface 4 Example The following example enables GVRP on the interface fe1 port 1 switch_a config set port gvrp enable fe1 switch_a config Per port setting GVRP applicant 1 Command Mode Configure mode Logon to Configure Mode...

Page 179: ..._NAME normal Specify dynamic GVRP multicast registration and deregistration on the port fixed Specify the multicast groups currently registered on the switch are applied to the port but any subsequent registrations or deregistrations do not affect the port Any registered multicast groups on the port are not deregistered based on the GARP timers forbidden Specify that all GVRP multicasts are deregi...

Page 180: ...fig ip igmp snooping querier switch_a config IGMP mode Passive 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use ip igmp snooping command to enable IGMP Snooping This command is given in the Global Config mode IGMP Snooping is enabled at the switch level Use the no ip igmp snooping command to...

Page 181: ...Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a config interface vlan1 1 switch_a config if 2 Usage Use ip igmp snooping fast leave command to enable IGMP Snooping fast leave processing Fast leave processing is analogous to immediate leave processing the IGMP group member...

Page 182: ...rval INTERVAL no ip igmp query interval INTERVAL 1 18000 Frequency in seconds at which IGMP host query messages are sent Default 125 seconds 4 Example The following example changes the frequency of sending IGMP host query messages to 2 minutes on vlan1 1 switch_a config interface vlan1 1 switch_a config if ip igmp query interval 120 switch_a config if IGMP querier Max response time 1 Command Mode ...

Page 183: ...ure Terminal Mode Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a config interface vlan1 1 switch_a config if 2 Usage Use ip igmp snooping mrouter interface command to statically configure the specified VLAN constituent interface as a multicast router interface for IGMP Snooping in that VLAN Use the no ip igmp snooping mrouter interf...

Page 184: ...sable report suppression 3 Command Syntax no ip igmp snooping report suppression 4 Example The following example enables report suppression for IGMPv2 reports on vlan1 1 switch_a config interface vlan1 1 switch_a config if ip igmp version 2 switch_a config if ip igmp snooping report suppression switch_a config if NTP RTC Time 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View...

Page 185: ...0 23 Specifies from 0 to 23 MINUTE 0 59 Specifies from 0 to 59 SECOND 0 59 Specifies from 0 to 59 4 Example The following example sets the time of RTC as July 20 2015 12 30 50 switch_a set clock 2015 7 20 12 30 50 switch_a NTP Status 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use ntp enabl...

Page 186: ... The following example specifies the IP address 192 168 1 100 of NTP server switch_a config ntp server 192 168 1 100 switch_a config Sync Time 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use ntp sync time command to synchronize time with NTP server 3 Command Syntax ntp sync time 4 Example T...

Page 187: ... polling interval 3 Command Syntax ntp polling interval MINUTE MINUTE 1 10080 The polling interval Enter a value in the range 1 to 10080 minutes 4 Example The following example specifies the polling interval 60 minutes switch_a config ntp polling interval 60 switch_a config Daylight Saving Mode 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt...

Page 188: ...date DAY MONTH HOUR MINUTE DAY MONTH HOUR MINUTE OFFSET TIMEZONE Specifies the daylight saving timezone DAY 1 31 Specifies from 1 to 31 MONTH 1 12 Specifies from January to December HOUR 0 23 Specifies from 0 to 23 MINUTE 0 59 Specifies from 0 to 59 OFFSET 1 1440 Specifies from 1 to 1440 minutes no clock summer time 4 Example The following example sets clock summer time TIMEZONE onehour as dayligh...

Page 189: ...Cat 5 Up to 328ft 100m 4 pair UTP STP Cat 5 Up to 328ft 100m MMF 50 or 62 5μm SMF 9 or 10μm MMF 50 or 62 5μm SMF 9 or 10μm LED Indicators Per unit Power Per port 10 100TX LINK ACT PoE 10 100TX 100FX BX SFP LINK ACT 10 100 1000TX 1000SX LX BX SFP LINK ACT Dimensions 2 56 W x 5 51 D x 6 69 H 65mm W x 140mm D x 170mm H Net Weight 2 2lbs 1Kg Power Input DC Jack 47 57VDC Terminal Block 47 57VDC Power C...

Page 190: ... Standards EN61000 4 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards Environmental Test Compliance IEC60068 2 6 Fc Vibration Resistance IEC60068 2 27 Ea Shock IEC60068 2 32 Ed Free Fall NEMA TS1 2 Environmental requirements for traffic control equipment ...

Page 191: ...witch User s Manual 190 Appendix A DB9 DCE pin assignment Pin no Name RS232 Signal name 1 DCD Data Carrier detect 2 RxD Received data 3 TxD Transmit data 4 N C 5 GND Signal ground 6 DSR Data set Ready 7 N C 8 CTS Clear to send 9 N C ...

Page 192: ...pe Skopje Europe Zagreb Europe Bratislava Poland EET 2EETDST Asia Nicosia EET Europe Minsk Europe Sofia Europe Athens Europe Vilnius Europe Chisinau Europe Istanbul Europe Kiev Europe Uzhgorod Europe Zaporozhye Europe Nicosia Asia Istanbul Europe Tiraspol Turkey GMT0BST Europe London Europe Dublin Eire Europe Belfast GB GB Eire WET0WETDST WET Atlantic Faeroe Atlantic Madeira Atlantic Canary PWT0PS...

Page 193: ... MST7 CST6CDT America Chicago America North_Dakota Center America Menominee America Costa_Rica America Managua CST6CDT US Central SystemV CST6CDT EST5EDT America New_York America Kentucky Louisville America Kentucky Monticello America Detroit America Pangnirtung America Louisville EST5EDT US Eastern US Michigan SystemV EST5EDT AST4ADT America Thule Atlantic Bermuda SystemV AST4ADT EST5 America Cor...

Page 194: ...Stanley America Asuncion Brazil West ACRE5 America Rio_Branco America Porto_Acre Brazil Acre NORO2 America Noronha Brazil DeNoronha CST4CDT Antarctica Palmer America Santiago Chile Continental EIST6EIDT Pacific Easter Chile EasterIsland Asia MST 8 Asia Kuala_Lumpur Asia Kuching CST 8 Asia Harbin Asia Shanghai Asia Chongqing Asia Urumqi Asia Kashgar Asia Hong_Kong Asia Macau Asia Macao Hongkong PRC...

Page 195: ...Etc Greenwich Etc GMT 0 Etc GMT 0 Etc GMT0 Africa Timbuktu GMT 0 GMT 0 GMT0 Greenwich Iceland UCT UTC Universal Zulu UCT1 Atlantic Cape_Verde Etc GMT 1 UCT2 Atlantic South_Georgia Etc GMT 2 UCT3 Antarctica Rothera America Belem America Cayenne America Paramaribo Etc GMT 3 UCT4 America Anguilla America Antigua America Barbados America Dominica America Grenada America Guadeloupe America Martinique A...

Page 196: ...ka Africa Harare Etc GMT 2 Libya UCT 3 Indian Comoro Africa Djibouti Africa Asmera Africa Addis_Ababa Africa Nairobi Indian Antananarivo Indian Mayotte Africa Mogadishu Africa Khartoum Africa Dar_es_Salaam Africa Kampala Antarctica Syowa Asia Bahrain Asia Kuwait Asia Qatar Asia Riyadh Asia Aden Etc GMT 3 UCT 4 Indian Mauritius Indian Reunion Indian Mahe Asia Muscat Etc GMT 4 UCT 5 Indian Kerguelen...

Page 197: ...Asia Tokyo Japan KST Asia Seoul Asia Pyongyang ROK UCT 3 30 Asia Tehran Iran UCT 4 30 Asia Kabul IST 2IDT Asia Jerusalem Asia Gaza Asia Tel_Aviv Israel CST6MEX America Cancun America Merida America Monterrey America Mexico_City America Lima Mexico General CST6 America Regina America Swift_Current Canada East Saskatchewan Canada Saskatchewan SystemV CST6 EET 2EETDST2 Europe Bucharest EET 2EETDST3 E...

Page 198: ...ingo America Port au Prince America Bogota North America Mexico PST8PDT_MX America Tijuana America Ensenada Mexico BajaNorte MST7MDT_MX America Chihuahua America Hermosillo America Mazatlan Mexico BajaSur CST6CDT_MX America Guatemala North America Turks and Caicos EST5EDT_TC America Grand_Turk Additions Since 10g RTM EST5EDT_INDIANA America Indiana Indianapolis America Indiana Marengo America Indi...

Page 199: ...198 Contact Information SIGNAMAX CONNECTIVITY SYSTEMS An AESP Company 16295 N W 13h Avenue Miami Florida 33169 U S A Phone 305 944 7710 Fax 305 949 4483 Sales 800 446 2377 Tech Support 800 446 2377 ext 201 E mail Http www signamax com info signamax com ...

Reviews: