Hardened Managed PoE Ethernet Switch
User’s Manual 166
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
snmp-server trap-type enable linkDown
command to enable link
down trap for SNMP.
Use the
no snmp-server trap-type enable linkDown
command to disable
link down trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable linkDown
4.
Example:
The following example enables link down trap for SNMP:
switch_a(config)#snmp-server trap-type enable linkDown
switch_a(config)#
Link Up Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
snmp-server trap-type enable linkUp
command to enable link up trap
for SNMP.
Use the
no snmp-server trap-type enable linkUp
command to disable link
up trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable linkUp
4.
Example:
The following example enables link up trap for SNMP:
switch_a(config)#snmp-server trap-type enable linkUp
switch_a(config)#
Authentication Failure Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Summary of Contents for 065-7700
Page 10: ...Hardened Managed PoE Ethernet Switch User s Manual 9 ...
Page 15: ...Hardened Managed PoE Ethernet Switch User s Manual 14 User s Manual RS 232 cable ...
Page 47: ...Hardened Managed PoE Ethernet Switch User s Manual 46 ...
Page 49: ...Hardened Managed PoE Ethernet Switch User s Manual 48 ...
Page 54: ...Hardened Managed PoE Ethernet Switch User s Manual 53 ...
Page 64: ...Hardened Managed PoE Ethernet Switch User s Manual 63 port ...
Page 70: ...Hardened Managed PoE Ethernet Switch User s Manual 69 ...
Page 77: ...Hardened Managed PoE Ethernet Switch User s Manual 76 ...
Page 88: ...Hardened Managed PoE Ethernet Switch User s Manual 87 ...