10.1
” WIRELESS HANDHELD OPERATING PANEL
HGW 1033-3
25.01.2019
Page 39
The confirmation switch is then only effective when the HGW is coupled with
a machine and the user is logged in.
The confirmation switch can be operated with the hand used to hold the operating panel.
The confirmation switch can be used as dead-man switch with a panic function.
6.9
Emergency Stop (illuminated)
The emergency stop has 2-channel construction. The top of the emergency stop is illuminated
when it is active. For application info, see 16.2.6 Emergency Stop.
CAUTION
Please note that the HGW 1033-3 emergency stop switch is simple an addi-
tional emergency stop switch. It cannot be installed as the only emergency
stop on a machine.
Veuillez noter que l'interrupteur d'arrêt d'urgence HGW 1033-3 est un simple
interrupteur d'arrêt d'urgence supplémentaire. Il ne peut pas être installé
comme seul arrêt d'urgence sur une machine.