48
Table 5: Meter Status Sub-Menu
Navigate to the Diagnostics (Sub Menu). Push enter key
to reach the Meter Status sub-menu.
The meter will report the status of your meter as either “No Issues” or it will display the detected
Error descriptions. If more than one issue is detected, they will all scroll together beneath the
“Meter Status” heading.
If errors are present, customers are urged to use the Sensor Tune menu and
SIP ValidCal Diagnostics to analyze the problem.
The following error descriptions may be present:
Flow Sensor
Temperature Issues
Temperature Overrange
Pressure Transducer Issues
Pressure Transducer Overrange
SD Card Issues
UART Issues
MCU Voltage Issues
Main Board Button Stuck
Digicomms Fail
Signal Noise
A description of each follows.
Flow Sensor Issues
Possible Cause of Error Code
1.
The flow sensor may have been damaged.
This can be caused by water hammer or excessive velocity.
Solution:
Go to the
Low/High
Sub-Menu (See Table 8) button, and check the highest velocity
recorded.
The max velocity spec is 30 fps for a liquid; 300 fps for a gas. If these velocities
have been exceeded, the sensor may have been damaged.
Pull the meter and check for visible damage.