27
main enclosure and two lids to be locked on the remote enclosure (if E4 feature was ordered)
enclosures in order to maintain the safety ratings.
The following warnings should be obeyed:
To minimize an electrostatic charging hazard on the exterior of the enclosures both the main and
remote (if E4 option ordered) enclosures should be connected to earth ground, see below for more
details.
1.
Earthing
: The Sierra Instruments units must be connected to a good quality earth. The
units are provided with internal and external earthing terminals.
2.
External Earthing
: The external earthing connections are located on the boss on the
outside of both the main housing and remote housing (E4 option if ordered) and consist
of an 18-8SS pan head Phillips screw (10-24 UNC-2B thread) and a serrated tooth #10
ring terminal for 16-14 AWG wire.
3.
Internal Earthing
: The internal earthing connection is located in the main and remote
(E4 option if ordered) housing terminal side and consist of an 18-8SS pan head Phillips
screw (10-24 UNC-2B thread) and a serrated tooth #10 ring terminal for 16-14 AWG
wire.
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS
PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD
—
SEE
INSTRUCTIONS
Figure 10. InnovaMass Main and Remote Enclosure Shown With Lid Locking Screw
Summary of Contents for InnovaMass 240i Series
Page 85: ...85 Appendix A Product Specifications ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 88: ...88 ...
Page 89: ...89 ...
Page 90: ...90 ...
Page 91: ...91 ...
Page 92: ...92 ...
Page 93: ...93 ...
Page 94: ...94 ...
Page 95: ...95 ...
Page 96: ...96 ...
Page 111: ...111 ...
Page 112: ...112 ...
Page 113: ...113 ...