Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Switch on
Yes
No
-
01
Closed-loop controlled mode on
Yes
No
-
02
Open-loop controlled mode master on
Yes
No
-
03
Open-loop controlled mode previous slave on
Yes
No
-
04
Open-loop controlled mode subsequent slave on
Yes
No
-
07
Open-loop controlled mode accept commutation angle
Yes
No
-
Dependency:
See also: p30475
p30477
CI: RAILCTRL velocity setpoint / v_set
All objects
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned32 / FloatingPoint32
Dynamic index: -
Function diagram: 7365
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: p2000
Expert list: 1
Min:
-
Max:
-
Factory setting:
1170[0]
Description:
Sets the signal source for the velocity setpoint.
Dependency:
Only active in the open-loop controlled mode.
p30480
RAILCTRL open-loop controlled mode specify commutation angle / Commut_ang spec
All objects
Can be changed: T
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
0.00 [°]
Max:
360.00 [°]
Factory setting:
0.00 [°]
Description:
Setting the commutation angle.
For a positive edge of p30475.7, this value is transferred into the commutation angle for open-loop controlled mode
(r30486).
Dependency:
See also: p30475, r30486
r30482.0...13
CO/BO: RAILCTRL status word / ZSW
All objects
Can be changed: -
Calculated: -
Access level: 3
Data type: Unsigned16
Dynamic index: -
Function diagram: 7363, 7364,
7365, 7366
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
-
Max:
-
Factory setting:
-
Description:
Display and BICO output for the actual status word RAILCTRL_ZSW of the sequence control.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Switched on
Yes
No
-
01
Closed-loop controlled mode active
Yes
No
-
02
Open-loop controlled mode master active
Yes
No
-
03
Open-loop controlled mode previous slave active
Yes
No
-
04
Open-loop controlled mode subsequent slave active
Yes
No
-
10
Closed-loop controlled mode previous slave active
Yes
No
-
11
Closed-loop controlled mode subsequent slave active
Yes
No
-
12
Slave mode active
Yes
No
-
Parameter
RAILCTRL
Function Manual, 09/2019, A5E38120767B
63