Commissioning
6
6.1
Commissioning overview
The following description specifies the usual sequence when commissioning the Technology
Extension RAILCTRL.
The "Examples for configuring RAILCTRL (Page 52)" also serve as commissioning guide.
The installed RAILCTRL Technology Extension is transferred using the "Load to file system"
function. This can be used for series commissioning.
Requirements
The following prerequisites must be satisfied in order to commission the RAILCTRL
Technology Extension:
● The Technology Extension is installed as technology package in STARTER, see "Installing
the OA Support Package in STARTER (Page 20)".
● The technology package is loaded into the Control Unit, see "Downloading the technology
● The Technology Extension is assigned to the intended drive object, see "Activating the
Technology Extension in the drive object (Page 22)".
Licensing
A License Key is required for the RAILCTRL Technology Extension:
You can generate the appropriate License Key using the WEB License Manager. To do this,
you require the Certificate of License (CoL).
The article number (MLFB) for the Certificate of License (CoL) is as follows:
6SL3077-0AA01-8AB0
You can use the license for the memory card in the following systems:
● SINAMICS S120 (CU320-2)
● SINAMICS Integrated (SIMOTION D4x5-2)
Note
Information and the procedure required for licensing can be found in the following reference:
● SINAMICS S120 Drive Functions Function Manual, Chapter "Licensing".
RAILCTRL
Function Manual, 09/2019, A5E38120767B
43
Summary of Contents for SINAMICS RAILCTRL
Page 1: ...Function Manual Rail Control RAILCTRL Edition SINAMICS 09 2019 www siemens com drives ...
Page 2: ......
Page 14: ...Safety instructions 2 3 Industrial Security RAILCTRL 12 Function Manual 09 2019 A5E38120767B ...
Page 104: ...Index RAILCTRL 102 Function Manual 09 2019 A5E38120767B ...
Page 105: ......