4. Because the communication for the previous and subsequent segments via a DRIVE-CLiQ
socket has already been configured in p30490[0..1], the setting of the connection direction
in p30452 is not possible. Consequently, set p30452[0] and p30452[1] to 0.
5. Set the coordinates and geometry data for each drive object as specified in the following
table:
Parameter Geometry data
Segment length
= 102 mm
Segment length
= 306 mm
p30460
RAILCTRL measuring range start
40
40
p30461
RAILCTRL primary section start
50
50
p30462
RAILCTRL measuring range length
122
326
p30463
RAILCTRL primary section length
102
306
p30464
RAILCTRL secondary section length
51
51
p30466
RAILCTRL hysteresis
0.5
0.5
p30467
RAILCTRL master/slave transition offset
0
0
p30472[0] Vibration compensation transverse voltage
-0.4
-0.4
p30472[1] Vibration compensation longitudinal voltage
-2
-2
The following diagram shows the coordinates and geometry data for example 2 with segment
length 306 mm.
6HJPHQWN
6HJPHQWN
6HJPHQWN
0HDVXULQJUDQJH
3ULPDU\VHFWLRQ
6HFRQGDU\VHFWLRQ
S
S
V>PP@
S
S
S
Figure 6-2
Example 2: Coordinates and geometry data
Commissioning
6.6 Examples for configuring RAILCTRL
RAILCTRL
56
Function Manual, 09/2019, A5E38120767B
Summary of Contents for SINAMICS RAILCTRL
Page 1: ...Function Manual Rail Control RAILCTRL Edition SINAMICS 09 2019 www siemens com drives ...
Page 2: ......
Page 14: ...Safety instructions 2 3 Industrial Security RAILCTRL 12 Function Manual 09 2019 A5E38120767B ...
Page 104: ...Index RAILCTRL 102 Function Manual 09 2019 A5E38120767B ...
Page 105: ......