Parameter Setting
Description
RAILCTRL parameters to the previous segment SERVO_02
p30452[0] r30451 (from
SERVO_02)
RAILCTRL adjacent segment assignment input, previous segment interconnected with
RAILCTRL adjacent segment assignment output from the previous segment
p30490[0] 999
RAILCTRL CU communication activation, previous segment: no communication via DRIVE-CLiQ
p30492[0] 0
RAILCTRL coordinate offset DRIVE-CLiQ setting, previous segment
RAILCTRL parameters to the subsequent segment (no following Control Unit)
p30452[1] 0
RAILCTRL adjacent segment assignment input, subsequent segment
p30490[1] 999
RAILCTRL CU communication activation, subsequent segment: no communication via DRIVE-
CLiQ
p30492[1] 0
RAILCTRL coordinate offset DRIVE-CLiQ setting, subsequent segment
Commissioning
6.6 Examples for configuring RAILCTRL
RAILCTRL
54
Function Manual, 09/2019, A5E38120767B