8.3.3.2
Parameterization
Parameterization menu structure
The menus that you can call from the "Parameterization" menu using the function keys are
described below.
3DUDPHWHUL]DWLRQ
,QGLYLG'2
$OO'2
3DUDPHWHUL]H
'2VHOHFWLRQ
3HUPDQHQWSDUDPHWHU
WUDQVIHU
0DLQPHQX
Figure 8-6
Parameterization menu structure
Calling up the parameterization menu
1. Press the "MENU" key.
2. Press the <▼> function key to select the "Parameterization" row. Press the <OK> function
key to confirm the selection.
3. Press the <▲> or <▼> function key to select the desired function. Press the <OK> function
key to confirm the selection.
Individual DO
The "Individual DO" function opens the parameter lists for the individual DriveObjects (DO).
1. Press the <▲> or <▼> function key to select the desired DO. Confirm the selection with <OK>.
2. Press the <▲> or <▼> function key to select the desired parameter. Alternatively, you can
select the parameter by entering the parameter number on the keypad. Parameters with
identical functions may exist with the same parameter number in more than one drive object
(e.g. p0005).
3. Press the <Change> function key to open the change window of the parameter. You can
change the parameter by assigning values or by making a selection from a list.
4. Press the <Help> function key to fetch information about the selected parameter.
Operation
8.3 Operation via the AOP30 operator panel
SINAMICS GM150 6SL3835-2LN44-2AA0