Deleting system-related data on the IPC using a script
1. Create a backup copy of the data storage medium for the IPC.
2. Activate the service mode (Page 42).
3. On the IPC desktop, open the "Troubleshooting" folder.
4. Select script "21_wipe_all_dsc_data_secure".
5. In the shortcut menu, execute command "Run as administrator".
The operation may take several minutes.
Data are securely deleted according to the NCSC-TG-025 standard of the National Computer
Security Center.
Deleting data of the components in the sensor box
CPU SIMATIC S7-1212C DC/DC/DC
1. Reset the CPU to the factory settings. To do this, follow the instructions in the CPU
SIPLUS CMS1200 SM1281
1. Delete all device data. To do this, follow the instructions provided in the component
documentation (Page 16) (keyword, "Data cleansing").
Maintenance
9.11 Deleting the data of the connectivity module
Operating Instructions, 06/2020