![Siemens SIMATIC S7-300 FM 350-1 Manual Download Page 53](http://html.mh-extra.com/html/siemens/simatic-s7-300-fm-350-1/simatic-s7-300-fm-350-1_manual_1265384053.webp)
Programming the FM 350-1
5.6 Technical specifications of the blocks
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
53
5.6
Technical specifications of the blocks
Table 5- 11 Technical Specifications for the Blocks
Technical data
FC CNT_CTRL
FC CNT_CTL1
FC CNT_CTL2
FC DIAG_INF
Block number
FC 0
FC 2
FC 3
FC 1
Version
3.0
3.0
3.0
3.0
Assignment in work
memory
540 bytes
894 bytes
1422 bytes
246 bytes
Assignment in load
memory
634 bytes
1062 bytes
1572 bytes
326 bytes
Assignment in data
area
70 bytes long data block that is specified when the FC is called
Assignment in local
data area
4 bytes
46 bytes
46 bytes
38 bytes
System function called –
SFC 6
(RD_INFO)
SFC 6
(RD_INFO)
SFC 51
RDSYSST
Isochronous mode
No
Yes
Yes
Yes
Non-isochronous
mode
Yes
Yes
No
Yes