Operating Modes, parameters and commands
7.4 Measuring modes
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
141
Limit Monitoring
The following value ranges are permitted for limit value monitoring:
Table 7- 33 Frequency Measurement: Value Ranges for Limit Monitoring
Encoder type
Low limit f
u
High limit f
o
5-V encoders
0 to 499 999 999 × 10
-3
Hz
f
u
+1 to 500 000 000 × 10
-3
Hz
24-V encoders
0 to 199 999 999 × 10
-3
Hz
f
u
+1 to 200 000 000 × 10
-3
Hz
Possible Measuring Ranges with Error Indication
Table 7- 34 Frequency Measurement: Measuring Ranges and Errors
Frequency f
min
Absolute error
Frequency f
min
Absolute error
0.1 Hz
±0.001 Hz
1 000 Hz
±0.18 Hz
1 Hz
±0.001 Hz
10 000 Hz
±1.8 Hz
10 Hz
±0.003 Hz
100 000 Hz
±18 Hz
100 Hz
±0.02 Hz
500 000 Hz
±90 Hz
Function of the DI Start and DI Stop Digital Inputs
You can choose between the following functions for the digital inputs:
●
Level-controlled hardware gate
●
Edge-controlled hardware gate
See section Command: Open and close gate (Page 149))
Function of Digital Output DO0
You can choose between the following functions for digital output DO0:
●
No comparison (no switching by limit value monitoring)
●
Measured value outside limits
●
Measured value under low limit
●
Measured value above high limit
(See the section Behavior of the Digital Outputs (Page 153))
Summary of Contents for SIMATIC S7-300 FM 350-1
Page 8: ...Table of contents FM 350 1 Counter module 8 Manual 05 2011 A5E03648639 01 ...
Page 186: ...Technical data 11 2 Technical data FM 350 1 Counter module 186 Manual 05 2011 A5E03648639 01 ...
Page 188: ...Replacement parts FM 350 1 Counter module 188 Manual 05 2011 A5E03648639 01 ...
Page 190: ...References FM 350 1 Counter module 190 Manual 05 2011 A5E03648639 01 ...
Page 194: ...Glossary FM 350 1 Counter module 194 Manual 05 2011 A5E03648639 01 ...