Operating Modes, parameters and commands
7.3 Count modes
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
125
Single Setting of the Counter with DI Set and Zero Mark
The following figure shows single setting of the counter with the zero mark. In the case
represented here, only ENSET_UP is set, i.e., the counter is set during up counting.
With the first rising pulse edge of the zero mark, the counter is set provided that ENSET_UP
and DI Set are similarly set.
If you want to set the counter again, you must first reset ENSET_UP and then set it again. If
DI Set is not set, setting is performed with the first zero mark after DI Set has been set. If
DI Set is set, setting is performed with the next zero mark.
(16(7B83
',6HW
&RXQWSXOVHV
=HURPDUN
&RXQWHUVHW
&RXQWHUVHW
&RXQWHU
QRWVHW
&RXQWHU
QRWVHW
&RXQWHU
QRWVHW
&RXQWHU
QRWVHW
Figure 7-25 Single Setting of the Counter with the Zero Mark