![Siemens Simatic S7-1500 CPU 1512C-1 PN User Manual Download Page 65](http://html.mh-extra.com/html/siemens/simatic-s7-1500-cpu-1512c-1-pn/simatic-s7-1500-cpu-1512c-1-pn_user-manual_1265380065.webp)
Technology functions
3.2 Pulse generators
CPU 1512C-1 PN (6ES7512-1CK01-0AB0)
Manual, 12/2017, A5E40898741-AA
65
Category
Parameter
Meaning
Value range
Default
Increments per revolu-
tion
The "Increments per
revolution" is used to
define the number of
increments per revolu-
tion (also in microstep
mode), which is re-
quired by the drive for a
revolution.
1 to 1,000,000
200
Fine resolution Bits in incr. actual value
(G1_XIST1)
The parameter defines
the number of bits for
the coding of the fine
resolution in the current
incremental value of
G1_XIST1.
0
0
Stop behavior Quick stop time
The parameter "Quick
stop time" defines the
time interval it should
take for the drive to go
from the maximum
speed to a standstill
(OFF3).
1 to 65 535 (ms)
1,000 (ms)
Hardware
inputs /
outputs
Reference switch input
The parameter "Refer-
ence switch input"
defines the hardware
input of the reference
switch.
[Input address of the reference
switch DI]
--
Edge selection refer-
ence switch
The parameter "Edge
selection reference
switch" defines the
edge type which is to
be detected by the
reference switch.
Rising edge
Rising edge
Falling edge
Measuring input
The parameter "Meas-
uring input" defines the
hardware input of the
measuring input.
[Input address of the measuring
input DI]
--
"Drive ready" input
The parameter ""Drive
ready" input" defines
the hardware input of
the input "Drive ready".
[Input addresses of the inputs
"Drive ready" DIn]
--
Pulse output A
for "PTO (pulse (A) and
direction (B))"
The parameter "Pulse
output A" defines the
hardware output for
PTO signal A.
[Output address DQ for PTO
signal A (output frequency
100 kHz)]
grayed out
Read only ac-
cess to the pa-
rameter
Direction output B
for "PTO (pulse (A) and
direction B))"
The parameter "Direc-
tion output B" defines
the hardware output for
PTO signal B.
[Output address 1 of the DQ for
PTO signal B (output frequency
100 kHz)]
Qn (output fre-
quency 100 kHz)
[Output address 2 of the DQ for
PTO signal B (output frequen-
cy 100 Hz)]
Summary of Contents for Simatic S7-1500 CPU 1512C-1 PN