Technical specifications
10.5 Contact assignment of the USB port
Mobile Client900RXA
Operating Instructions, 07/2015, A5E36360099-AA
149
Connection box
Ambient conditions
Permissible range
Comments
Temperature in operation
0 to 55 °C
For control cabinet mounting see
section "Special operating modes
(Page 124)
Temperature during
storage/transportation
-45 °C to 70 °C
Relative humidity, operation, and
transport/storage
35% to 85%
Without condensation,
corresponds to a relative
humidity, exposure level 2
conforming to IEC 61131, part 2
Atmospheric pressure
1,080 hPa to 795 hPa
Corresponds to an altitude of
–1,000 to 2,000 m
Pollutant concentration
SO
2
< 0.5 ppm
Relative humidity < 60%
no condensation
Test: 10 cm
3
/m
3
; 10 days
H
2
S < 0.1 ppm
Relative humidity < 60%
no condensation
Test: 1 cm
3
/m
3
; 10 days
10.5
Contact assignment of the USB port
USB socket
Contact
Assignment
1
+5 VDC, out (max. 500 mA)
2
USB-DN
3
USB-DP
4
GND