Technical specifications of the wall-mounting brackets
Wall-mounting bracket, weight without packaging Approx. 900 g
Magnet wall bracket, weight without packaging
Approx. 850 g
10.4.4
Ambient conditions for transport and storage
Mechanical and climatic transport and storage conditions
The transportation and storage conditions of this HMI device exceed requirements in
accordance with IEC 61131-2. The following specifications apply to the transportation and
storage of an HMI device in its original packaging.
The climatic conditions comply with the following standards:
●
IEC 60721-3-3, Class 3K7 for storage
●
IEC 60721-3-2, Class 2K4 for transport
The mechanical conditions are compliant with IEC 60721-3-2, Class 2M2.
The following table shows the transport and storage conditions for the Mobile Client.
Type of condition
Permissible range
Free fall
≤ 1
m
Temperature
–25 to +70 °C
Atmospheric pressure
1080 to 660 hPa,
corresponds to an elevation of -1000 to 3500 m
Relative humidity
5 to 95%, without condensation
Sinusoidal vibration in accordance with
IEC 60068-2-6
5 to 8.4 Hz: 3.5 mm
8.4 to 150 Hz: 9.8 m/s
2
Shock in accordance with IEC 60068-2-27
15 g, 11 ms, 1000 shocks
The following table shows the transportation and storage conditions for the terminal device.
Type of condition
Permissible range
Free fall
≤ 1
m
Temperature
–40 to +70 °C
Atmospheric pressure
1080 to 660 hPa,
corresponds to an elevation of -1000 to 3500 m
Relative humidity
5 to 95%, without condensation
Sinusoidal vibration in accordance with
IEC 60068-2-6
5 to 8.4 Hz: 3.5 mm
8.4 to 150 Hz: 9.8 m/s
2
Shock as defined by IEC 60068-2-27
15 g, 11 ms, 1000 shocks