![Siemens S5-135U System Manual Download Page 306](http://html.mh-extra.com/html/siemens/s5-135u/s5-135u_system-manual_377341306.webp)
7-16
System Manual
C79000-G8576-C199-06
Function
Jumper Settings
Interface X3/X4
– Switched on
– Switched off
1)
X22/X21 at “ON”
X22/X21 at “OFF”
ON
OFF
ON
OFF
“I/Os not ready” message relayed
– no
– yes
X15 no jumpers
X15 jumper 1-2
1
2
3
1
2
3
“I/Os not ready” message when
– 1 interface not ready
– 2 interfaces not ready
X14 jumper 1-2
X14 jumper 2-3
1
2
3
1
2
3
Set cable length between 304 / 314
– 0 to 100 m
– 100 to 250 m
– 250 to 450 m
– 450 to 600 m
X11
Jumper 3-4
Jumper 5-6
Jumper 7-8
Jumper 9-10
9 7 5 3 1
10 8 6 4 2
1)
Jumper X22 is assigned to interface X3.
Jumper X21 is assigned to interface X4
All other jumpers and switches must remain at the factory settings.
Purpose of the
Jumpers
Interface Modules
Summary of Contents for S5-135U
Page 10: ...x SystemManual C79000 G8576 C199 06 Contents ...
Page 18: ...1 8 SystemManual C79000 G8576 C199 06 Notes on Using this Manual and on the CE Symbol ...
Page 66: ...3 40 SystemManual C79000 G8576 C199 06 Installation Guidelines ...
Page 496: ...9 114 SystemManual C79000 G8576 C199 06 Analog Input Output Modules ...
Page 536: ...11 24 SystemManual C79000 G8576 C199 06 Connector Assignments ...
Page 558: ...Index 8 SystemManual C79000 G8576 C199 06 Index ...