6/166
Siemens Building Technologies
Basic Documentation RVA47.320
CE1P2379E
HVAC Products
Contents
15.07.2002
5.2
Maximum limitation of the boiler temperature setpoint ................................112
5.3
Pump overrun time.......................................................................................113
5.4
Minimum limitation of the boiler return temperature.....................................113
5.5
Calibration of actual output range of BMU 1-4.............................................114
Heating circuit values ...................................................................................................115
5.6
Gain factor of room influence (KORR) .........................................................115
5.7
Constant for quick setback (KON) ...............................................................116
5.8
Boost of room temperature setpoint.............................................................117
5.9
Frost protection for the plant ........................................................................118
5.10
Overtemperature protection for the pump heating circuit.............................119
5.11 Heat
gains....................................................................................................120
5.12
Adaption sensitivity 1 ...................................................................................120
5.13
Adaption sensitivity 2 ...................................................................................121
D.h.w. values ...............................................................................................................123
5.14
Maximum nominal setpoint of d.h.w. temperature .......................................123
5.15
Switching differential of the d.h.w. temperature ...........................................123
5.16 Legionella
function .......................................................................................124
5.17
Setpoint of the legionella function ................................................................125
5.18
Protection against discharging of d.h.w. ......................................................125
Cascade settings .........................................................................................................127
5.19
Cascade management strategy ...................................................................127
5.19.1
Type of lead boiler operation .......................................................................128
5.19.2 Running
time
strategies ...............................................................................129
5.20
Lower limit of output range (Pmin) ...............................................................131
5.21
Upper limit of output range (Pmax) ..............................................................132
5.22
Mandatory time on basic stage ....................................................................132
5.23
Minimum temperature differential at the pressureless header.....................133
Configuration of plant ...................................................................................................134
5.24 Continuous
display.......................................................................................134
General values .............................................................................................................135
5.25 Software
version ..........................................................................................135
5.26
Device operating hours ................................................................................135
6
Functions with no settings............................................................................136
6.1 Chimney
sweep ...........................................................................................136
6.2
Generating the boiler temperature setpoint .................................................136
6.3
Automatic 24-hour heating limit ...................................................................137
6.3.1
Without room influence ................................................................................137
6.3.2
With room influence .....................................................................................138
6.4
Quick setback with room sensor ..................................................................139
6.5 D.h.w.
push ..................................................................................................140
6.6 Pump
kick ....................................................................................................141
6.7
Protection against discharging after d.h.w. heating .....................................141
6.8
Overview of pump operation ........................................................................142
6.9 Frost
protection ............................................................................................143
6.9.1
For the boiler................................................................................................143
6.9.2
For the d.h.w. ...............................................................................................143
7 Application
examples ...................................................................................144
7.1
Plant types RVA47.320 - no. 27...................................................................145
7.2
Plant types RVA47.320 - no. 28...................................................................146
7.3
Plant types RVA47.320 - no. 29...................................................................147
7.4
Plant types RVA47.320 - no. 30...................................................................148