RUGGEDCOM ROS
User Guide
Chapter 1
Introduction
SNMP Traps
15
Trap
MIB
fallingAlarm
lldpRemoteTablesChange
LLDP-MIB
The device also generates the following proprietary traps:
Table: Proprietary Traps
Trap
MIB
genericTrap
powerSupplyTrap
swUpgradeTrap
cfgChangeTrap
weakPasswordTrap
defaultKeysTrap
RUGGEDCOM-TRAPS-MIB
Generic traps carry information about events in their severity and description objects. They are sent at the same
time an alarm is generated for the device. The following are examples of RUGGEDCOM generic traps:
NOTE
Information about generic traps can be retrieved using the CLI command
alarms
. For more
information about the
alarms
command, refer to
Section 2.6.1, “Available CLI Commands”
.
Table: Generic Traps
Trap
Severity
heap error
Alert
NTP server failure
notification
real time clock failure
Error
failed password
Warning
MAC address not learned by switch fabric
Warning
BootP client: TFTP transfer failure
Error
received looped back BPDU
Error
received two consecutive confusing BPDUs on port, forcing down
Error
GVRP failed to learn – too many VLANs
Warning
The device generates the following traps when specific events occur:
Table: Event-Based Traps
Trap
MIB
Event
rcRstpNewTopology
RUGGEDCOM-STP-MIB
This trap is generated when the device
topology becomes stable after a topology
change occurs on a switch port.