CAUTION!
Do not downgrade the RUGGEDCOM ROS boot version.
1. Disconnect the device from the network.
2. Log in to the device as an admin user. For more information, refer to
.
3. Make a local copy of the current configuration file. For more information, refer to
.
IMPORTANT!
Never downgrade the RUGGEDCOM ROS software version beyond RUGGEDCOM ROS v4.3
when encryption is enabled. Make sure the device has been restored to factory defaults before
downgrading.
4. Restore the device to its factory defaults. For more information, refer to
Section 3.3, “Restoring Factory
.
5. Upload and apply the older firmware version and its associated FPGA files using the same methods used to
install newer firmware versions. For more information , refer to
Section 3.11.1, “Upgrading Firmware”
.
6. Press
Ctrl-S
to access the CLI.
7. Clear all logs by typing:
clearlogs
8. Clear all alarms by typing:
clearalarms
IMPORTANT!
After downgrading the firmware and FPGA files, be aware that some settings from the previous
configuration may be lost or reverted back to the factory defaults (including user passwords if
downgrading from a security related version), as those particular tables or fields may not exist in
the older firmware version. Because of this, the unit must be configured after the downgrade.
9. Configure the device as required.
Section 3.12
Resetting the Device
To reset the device, do the following:
1. Navigate to
Diagnostics
»
Reset Device
. The
Reset Device
form appears.