Chapter 4
System Administration
RUGGEDCOM ROS
User Guide
120
Configuring an Alarm
9
8
7
6
5
4
3
2
1
Figure 70: Alarms Form
1.
Name Box
2.
Level Box
3.
Latch Box
4.
Trap Box
5.
Log Box
6.
LED & Relay Box
7.
Refresh Time Box
8.
Apply Button
9.
Reload Button
3. Configure the following parameter(s) as required:
Parameter
Description
Name
Synopsis:
Any 34 characters
Default:
sys_alarm
The alarm name, as obtained through the
alarms
CLI command.
Level
Synopsis:
{ EMRG, ALRT, CRIT, ERRO, WARN, NOTE, INFO, DEBG }
Severity level of the alarm:
• EMERG - The device has had a serious failure that caused a
system reboot.
• ALERT - The device has had a serious failure that did not cause a
system reboot.
• CRITICAL - The device has a serious unrecoverable problem.
• ERROR - The device has a recoverable problem that does not
seriously affect operation.
• WARNING - Possibly serious problem affecting overall system
operation.
• NOTIFY - Condition detected that is not expected or not
allowed.
• INFO - Event which is a part of normal operation, e.g. cold start,
user login etc.
• DEBUG - Intended for factory troubleshooting only.
This parameter is not configurable.
Latch
Synopsis:
{ On, Off }
Default:
Off
Enables latching occurrence of this alarm in the Alarms Table.
Trap
Synopsis:
{ On, Off }
Default:
Off
Enables sending an SNMP trap for this alarm.
Log
Synopsis:
{ On, Off }
Default:
Off