![Siemens RUGGEDCOM ROS v4.3 User Manual Download Page 228](http://html.mh-extra.com/html/siemens/ruggedcom-ros-v4-3/ruggedcom-ros-v4-3_user-manual_385657228.webp)
Chapter 5
Setup and Configuration
RUGGEDCOM ROS
User Guide
212
Configuring LLDP for an Ethernet Port
Section 5.7.3
Configuring LLDP for an Ethernet Port
To configure LLDP for a specific Ethernet Port, do the following:
1. Navigate to
Network Discovery
»
Link Layer Discovery Protocol
»
Configure Port LLDP Parameters
. The
Port LLDP Parameters
table appears.
Figure 144: Port LLDP Parameters Table
2. Select a port. The
Port LLDP Parameters
form appears.
5
4
3
2
1
Figure 145: Port LLDP Parameters Form
1.
Port Box
2.
Admin Status List
3.
Notifications Options
4.
Apply Button
5.
Reload Button
3. Configure the following parameter(s) as required:
Parameter
Description
Port
Synopsis:
1 to maximum port number
Default:
1
The port number as seen on the front plate silkscreen of the
switch.
Admin Status
Synopsis:
{ rxTx, txOnly, rxOnly, Disabled }
Default:
rxTx