For remote totalization, the contact closure duration (P643) is automatically calculated
upon entry of the design rate (P011) and remote totalizer (P638) parameters, so that the
duration of contact closure allows the relay response to track the total up to 150% of the
design rate. The value can be changed to suit specific contact closure requirements, such
as in the case of programmable logic controllers. If the duration selected is inappropriate,
the next possible duration is automatically entered.
The totalizers are reset through the master reset (P999), the totalizer reset (P648) or
through the keypad.
•
master reset: the reset of all totalizer functions is included in the master reset.
•
totalizer reset: totalizer reset can be used to resets internal totalizers 1 and 2, or
totalizer 2 independently. Resetting the internal totalizers 1 and 2
resets the internal registers for external totalizers 1 and 2.
•
keypad: pressing
while in the RUN mode resets internal totalizer 1
Placing the internal totalizers on to the display scroll of the RUN mode is controlled by the
totalizer display parameter (P647). This displays either one or both totalizers.