7ML19985CN01
Milltronics SF 500 – INSTRUCTION MANUAL
Page 31
mm
mmm
Reca
libr
at
ion
Calculate the span adjust value:
% span adjust =
SF 500 – material sample weight x 100
material sample weigh
e.g. (428.5-423.0)x100
423
=1.3%
Access P019 and enter EDIT mode
Press
P019 Manual Span Adjust
E
Select 1-% Change 2-Material Test
0
P598 Span Adjust Percentage
V
Enter Calc/- error
0.00
0
kg / lb
kg / lb
1. zero calibration
start total
empty scale
4. weigh material
3. stop material feed
2. RUN mode