206_58300000141095_ara_en_k.doc – 04.10.a
Seite 44 von 113
3.12.1.1 Connection´s colours in englisch
In order to make the connections easier, the relay comes with colours
printed on module in englisch.
3.12.1.2 Polarity for the oval inductors
If the inductor´s connections are not correct, the polarity from the
current that goes into the inductor can change and turn in the opposite
direction
It can be observed if we put a bräter cookware above the
combisurface and we can see how are the bubbles that appear.
3.12.1.3 New error for this relay module: e9
•
This new error show us that there is a stickied relay in the new
module. Swith off and swith on again the hob
Steps to check:
•
Possible bad connection in control cable.
•
Possible bad connection in power cables
•
Stickied relay=> change relay module
Summary of Contents for EH675TK11E
Page 69: ...206_58300000141095_ara_en_k doc 04 10 a Seite 69 von 113 5 7 6 Checklist for induction hobs ...
Page 70: ...206_58300000141095_ara_en_k doc 04 10 a Seite 70 von 113 ...
Page 71: ...206_58300000141095_ara_en_k doc 04 10 a Seite 71 von 113 ...
Page 72: ...206_58300000141095_ara_en_k doc 04 10 a Seite 72 von 113 ...
Page 73: ...206_58300000141095_ara_en_k doc 04 10 a Seite 73 von 113 ...
Page 74: ...206_58300000141095_ara_en_k doc 04 10 a Seite 74 von 113 ...
Page 75: ...206_58300000141095_ara_en_k doc 04 10 a Seite 75 von 113 Can clamping claws be attached ...