RXB (KNX) Applications library
CLC and RAD description of functions for CC-02 CM110384en_03
Building Technologies
Contents
28 Feb 2009
Third-party (S-mode) examples ..................................................................53
Determine the room operating mode with Synco (LTE mode).................... 55
Local control of room operating mode via window contact input ................ 56
Central room operating mode control via
Central control of room operating mode via room operating mode input... 57
Local control of room operating mode via presence detector..................... 58
Local control of room operating mode with a room unit.............................. 59
Determine the room operating mode without a bus (stand-alone).............. 62
Local control of room operating mode via a window contact input ............ 63
Local control of room operating mode via presence detector..................... 63
Local control of room operating mode with room unit................................. 64
Temperature measurement...................................................................... 74
Room temperature measurement............................................................... 74
Local temperature sensor at PPS2 interface .............................................. 74
Local temperature sensor at analog input .................................................. 74
Averaging analog input & PPS2 interface................................................... 75
Temperature sensor outputs on the Konnex bus........................................ 76
Temperature sensor input from Konnex bus............................................... 77
Outside air temperature via Konnex bus (CLC02, RAD01) ........................ 78
Values representing radiator valve actuator positions ................................ 83
Override radiator valve actuators................................................................ 84
Select actuator types for chilled ceiling....................................................... 87
Values representing chilled ceiling valve actuator positions....................... 88
Override chilled ceiling valve actuators....................................................... 90
Central/passive dewpoint monitoring.......................................................... 91
Chilled ceiling and radiator 4-pipe (CLC02)................................................ 92
Configuration and parameterization............................................................92
Presence detector (S-mode).......................................................................96
Window switch (LTE mode) ........................................................................ 98
Presence detector (LTE mode)...................................................................98
Dewpoint sensor (LTE mode) .....................................................................98