Menu
code
Device function,
Parameters
Description
Factory setting
Setting options
Read
or write
6.5.6.3
TOF down 3
TIME OF FLIGHT (TOF) of third path
downstream
Value in ns
Read
6.5.6.4
TOF down 4
TIME OF FLIGHT (TOF) of fourth path
downstream
Value in ns
Read
6.5.7
Delta TOF
TIME OF FLIGHT (TOF) difference
Value in ns
Read
6.5.7.1
Delta TOF 1
TIME OF FLIGHT (TOF) difference of
first path (up - down)
Value in ns
Read
6.5.7.2
Delta TOF 2
TIME OF FLIGHT (TOF) difference of
second path (up - down)
Value in ns
Read
6.5.7.3
Delta TOF 3
TIME OF FLIGHT (TOF) difference of
third path (up - down)
Value in ns
Read
6.5.7.4
Delta TOF 4
TIME OF FLIGHT (TOF) difference of
fourth path (up - down)
Value in ns
Read
6.6
Zero Trim
6.6.1
Zero Pt.Offset
6.6.1.1
Zr.Pt.Offset 1
Zero offset of first path
Depends on factory
calibration, for exam‐
ple +0.000 ns
-50.000 ns to
+50.000 ns
Write
6.6.1.2
Zr.Pt.Offset 2
Zero offset of second path
Depends on factory
calibration, for exam‐
ple +0.000 ns
-50.000 ns to
+50.000 ns
Write
6.6.1.3
Zr.Pt.Offset 3
Zero offset of third path
Depends on factory
calibration, for exam‐
ple +0.000 ns
-50.000 ns to
+50.000 ns
Write
6.6.1.4
Zr.Pt.Offset 4
Zero offset of fourth path
Depends on factory
calibration, for exam‐
ple +0.000 ns
-50.000 ns to
+50.000 ns
Write
6.6.2
Stand.Dev.
6.6.2.1
Stand.Dev. 1
Standard deviation for path 1
Typical: +0.000 ns
Read
6.6.2.2
Stand.Dev. 2
Standard deviation for path 2
Typical: +0.000 ns
Read
6.6.2.3
Stand.Dev. 3
Standard deviation for path 3
Typical: +0.000 ns
Read
6.6.2.4
Stand.Dev. 4
Standard deviation for path 4
Typical: +0.000 ns
Read
6.6.3
Zero Trim
"Start sero tr."
Initiates a device specific adjustment
cycle (zero trim processing) that de‐
termines the true zero point value.
Only during no-flow process condi‐
tions!
Start
Status is shown as:
Running / Finished
Write
6.6.4
Undo zero tr.
Undo last zero trim
After choice shows
"Zero Trim OK"
Write
6.7
Trim parameter
6.7.1
Error Filter
HMI menu structure
D.1 Menu items (FW Rev. 4.00.00)
SITRANS FUS060 with PROFIBUS PA
Operating Instructions, 09/2021, A5E02225054-AD
115