System unit
Installing a module
Installing a module
!
Modules with a power dissipation of over 20 W must be inserted in the lowest slot.
The maximum permissible power dissipation in the two lowest slots is 40 W, and a
value of 25 W may not be exceeded in the lower of these.
Open the housing as described under "Opening the system unit".
Remove the screw and the rear slot cover plate.
!
Do not throw the slot cover plate away. If you ever remove the module, you will
have to replace the cover plate to ensure the required cooling effect.