background image

26

MSA400 smart 

Installation and operating instructions

05.2017

16. Information concerning product liability

16.1 Intended use

Any use of this product that is not in accordance with its correct use, or any adaptation of or modification to the product and its 
associated components for which the express consent of SIEGENIA has not been obtained, is strictly prohibited. SIEGENIA 
accepts no liability whatsoever for any material losses or injury to people caused by failure to comply with this stipulation.

16.2 Product liability

Our products are guaranteed – subject to correct installation and proper use – for a period of one year from the date of receipt 
by a company (according to our general terms and conditions) or as otherwise agreed, and for a period of two years for end 
consumers, in accordance with statutory provisions. As part of our ongoing improvements, we reserve the right to replace 
individual components or entire products. Consequential losses resulting from defects are excluded from the warranty within the 
limits of the law. The warranty shall become void if modifications that are not authorised by us or have not been described in this 
documentation are performed on the product and/or individual components, or if the product and/or individual components 
is/are dismantled or (partly) dismantled, and the defect is due to the changes made.

16.3 Disclaimer of liability

The product and its components are subject to stringent quality controls. As a result, they function reliably and safely when 
used correctly. 
Our liability for consequential losses and/or claims for damages is excluded, except in the case of wilful misconduct or gross 
negligence, or where we are responsible for injury to life, physical injury or damage to health. Strict liability under the 
German Product Liability Act (Produkthaftungsgesetz) remains unaffected. Liability for the culpable violation of significant 
contractual obligations also remains unaffected; liability in this case is limited to losses that are specific to the contract and 
that could have been foreseen. The above regulations do not imply a change in the burden of proof to the detriment of the 
consumer.

16.4 Environmental protection

Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act, SIEGENIA will 
continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are 
hazardous to the environment as soon as this becomes technically feasible.  
Electrical products should not be disposed of as household waste.

17. Feedback on documentation

We welcome your comments and suggestions on how to improve our documentation. Please email your comments to documen-
[email protected].

Summary of Contents for Drive Series

Page 1: ...DRIVE Motorised Sliding System MSA400 smart Window systems Door systems Comfort systems INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ...ite risk and hazard analysis 8 7 Installation 9 8 Commissioning 18 9 Operation 20 10 Programming special functions 22 11 Reset the sash position 22 12 Care and maintenance 23 13 Rectification of malfu...

Page 3: ...not suitable for use in swimming pools and or damp rooms Special designs are possible and permitted only upon request and after having been tested by SIEGENIA The MSA400 smart must only be operated wi...

Page 4: ...y system or building wiring system All pole safety isolation is required when the mains cable is laid on site because the power supply does not have a separate line disconnector Connect in wall supply...

Page 5: ...ide drive SA with terminal board allows for the integration of a light curtain If an object is placed in the path of the sliding sash it will be stopped immediately The sliding sash can be moved into...

Page 6: ...nal safety requirements apply the optional terminal board must be ordered Also available prepared to be equipped with a light curtain To prevent injuries and damage the safety cut off function is perf...

Page 7: ...twork connection cable with Euro plug On slide drive SA 5 m cable length for 230 V AC 3 1 Packer 2 5 5 8 or 10 mm thick depending on profile system for catch on sliding sash 4 1 Catch base for sliding...

Page 8: ...tection or trained personnel Special structural conditions Type of access control Requirements for added safety can be met with a light curtain 6 2 Instructions for assembly and installation Use flexi...

Page 9: ...pported especially with wide or heavy sliding elements e g 400 kg The displacement force must not be 60 N The cable routing of the cable in the sliding sash must be checked prior to assembly The slidi...

Page 10: ...400 smart system is delivered as standard with a mains cable The cable outlet for scheme A is always at the top of the slide drive SA on the locking side Fig 1 for scheme C it can be located on the ou...

Page 11: ...mm away from the inside frame edge Fig 4 All pole safety isolation is required if the customer is routing the mains cable The isolated end of the mains cable must be located inside the power supply h...

Page 12: ...nd drilling diameters for the holes of the catch on the Sliding sash fig for timber profile DIN left DIN right is a mirror image Adjustment dimension X Cable feed through 15 Supporting peg Catch base...

Page 13: ...edge by 2 mm see Fig A 2 mm 2 mm 2 mm A Fig for positioning DIN left DIN right is a mirror image Inside frame edge slide drive SA Cover cap SA Cowl length External edge mounting angle Inside frame ed...

Page 14: ...for installation of the MSA400 smart on our download portal downloads siegenia com de 00007 index html 1 Fixing the slide drive SA to the mounting angle at screw level A or B 2 Set the catch down on t...

Page 15: ...using a wall or key switch not included in scope of delivery the cable must be connected in the power supply of the slide drive SA 1 Unscrew the fixing screws on the power supply cover and remove the...

Page 16: ...d off 1 Unscrew the fixing screws on the power supply cover and remove the power supply cover 2 Disassemble and remove the plug cable that comes standard in the power supply 3 Run the concealed mains...

Page 17: ...eceiver 1 24 V 2 Input light curtain 2 RX 3 Not used 4 GND 5 24 V 6 Input light curtain 1 RX 7 Not used 8 GND 9 Receiver inside 10 Receiver outside 1 2 3 4 5 6 7 8 13 14 15 16 17 18 19 20 9 10 11 12 T...

Page 18: ...nly has to be performed when commissioning the equipment Any tasks relating to commissioning may only be completed by qualified professionals 8 2 Reference run 1 The sliding sash must be in the CLOSED...

Page 19: ...he Prog button the LED flashes green 4 Press and hold the operating push button for approx 11 seconds until a short acoustic signal sounds 4 times in successi on 5 Release the operating push button 6...

Page 20: ...iding sash is opening press the operator push button once The sliding sash stops 1 x 9 3 Opening the sliding sash to the intermediate position Note The desired intermediate position must be programmed...

Page 21: ...sh optional only with supplementary locking motor Note This function must be programmed on the MSA400 smart system before it is carried out see Teach in close function without locking on 22 With slidi...

Page 22: ...once 6 The sliding sash stops and the intermediate position is stored The sliding sash can now be opened up to the intermediate position 1 2 3 ca 8 Sek BEEP 1x BEEP 2x BEEP 3x 4 5 6 1 x 11 Reset the s...

Page 23: ...connection to the 230 V AC mains power supply switch off all poles of the feeder The fuses may need to be removed 12 1 Cleaning Important When cleaning the MSA400 smart do not allow liquids to get in...

Page 24: ...least 10 seconds then start reference and calibration run see pages 18 if the problem reoccurs contact Service MSA400 smart aborts closing opening and moves in opposite direction for 4 seconds Off Obs...

Page 25: ...ure range 5 C to 50 C Jam protection Electronic overload cut off device current limiter in accor dance with standard Protection class IP20 for dry locations Connection to AC mains power supply at fact...

Page 26: ...onents is are dismantled or partly dismantled and the defect is due to the changes made 16 3 Disclaimer of liability The product and its components are subject to stringent quality controls As a resul...

Page 27: ...otocol 14 457 The machine may only be put into operation when incomplete if it has been ascertained if applicable that the machine into which it is to be installed conforms to the specifications of th...

Page 28: ...85 4861080 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4...