22
MSA400 smart
Installation and operating instructions
05.2017
10. Programming special functions
10.1 Teaching-in the intermediate position
1. Close sliding sash completely (CLOSED position).
2. Press the
Prog
button; the LED flashes green.
3. Press and hold the operating push button for approx. 8 seconds until a short acoustic signal sounds 3 times in succession.
4. Release operating push button; the sliding sash opens.
5. At the desired intermediate position, press the operating push button once.
6. The sliding sash stops and the intermediate position is stored. The sliding sash can now be opened up to the intermediate
position.
1.
2.
3.
ca. 8 Sek.
BEEP
1x
BEEP
2x
BEEP
3x
4.
5.
6.
1 x
11. Reset the sash position
11.1 Performing a reference run
1. The sliding sash must be in the CLOSED position in order to begin the reference run. If necessary, slide the sash to this
position manually.
2. Press the
RESET
button; the LED flashes red.
3. Press the operating push button. The reference run starts. During the reference run, the sash is unlocked and then locked
again.
4. Wait approx. 4 - 10 seconds until the sash is locked.
5. The LED switches off once the reference run is complete.
1.
2.
3.
4.
4 - 10 Sek.