Installation and operating instructions
MSA400 smart
05.2017
17
7.7 Installing the light curtain
Alterations must be made to the MSA400 smart in order to operate it with a light curtain
The suitable light curtain can be ordered from:
CEDES GmbH
Elektronische Systeme
Elzmatten 6
D-79365 Reinhausen
Light curtain
=
=
Light curtain
Terminal board for connecting light curtain (plugs or terminals)
Receiver
1
+ 24 V
2
Input light curtain 2 (RX)
3
Not used
4
GND
5
+ 24 V
6
Input light curtain 1 (RX)
7
Not used
8
GND
9
Receiver, inside
10
Receiver outside
1
2
3
4
5
6
7
8
13
14
15
16
17
18
19
20
9
10
11
12
Transmitter
11
Transmitter, inside
12
Transmitter
outside
13
GND
14
Not used
15
Test
16
+ 24 V
17
GND
18
Not used
19
Test
20
+ 24 V
On the slide drive SA, a jumper must be switched for operation with a light curtain.
3
2
1
B
A
Jumper position Operating mode
1
With reduced traverse speed
2
"Normal operation" without light curtain
3
With light curtain
Item
Designation
A
Sockets
B
Connecting clamps