Chapter
10
Operating Instructions
Radio Frequency Identification RFH620 Interrogator
42
8013171/ZO93/2017-08-08
©
SICK AG
•
Germany
•
All rights reserved
Appendi
x
interfaces or serial data interfaces (e.g. Ethernet address) are overwritten. The
connection(s) to the RFH620 might be interrupted and has (have) to be reconfigured.
¾
Application-specific default setting (LOAD APPLICATION DEFAULT)
SOPAS-ET resets the parameter values of the RFH620 but does not change the
communication parameters. Settings which have been previously made for the
communication parameters of the Ethernet interfaces or serial data interfaces are kept
and the current connection(s) to the RFH620 remain(s) established.
1. In order to discard changes to the parameter set as described above, select the
corresponding command in the menu bar under RFH620.
The SOPAS-ET configuration software loads the default setting from the RFH620 and
displays the parameter values in the register tabs. In the RFH620, the default setting
will first be active in the temporary main memory only.
The default setting can also be saved on or printed via the PC, chapter “Save, display
and print the current parameter set”.
2. In the menu bar under TOOLS select the command LOGIN DEVICE.
3. In the dialog window under USERLEVEL in the list box select the entry AUTORIZED
CLIENT.
If the parameter set is password-protected, enter the password "client" in PASSWORD.
4. Click on OK to confirm the dialog window.
5. In the menu bar under RFH620 select the command PARAMETER/SAVE
PERMANENT.
The SOPAS-ET configuration software transfers the default setting to the permanent
parameter memory (PROM) of the RFH620.
If the bar code scanner is connected to a connection module CDB620/CDM420 with
parameter memory module CMC600, the parameter set is also saved permanently in
the CMC600.
Once the default setting has been restored, password-protection is deactivated.