6.4.2 Configure the RFH620
All configurable parameters for the RFH620 are grouped into a device description (jar-
file) for the SOPAS-ET configuration software. The device description's project tree
acts as a guideline for the configuration.
The function of each respective parameter is explained in a context-sensitive manner in
an online help (F1 key). The valid value range and the default setting list the display
window PARAMETER INFO (right mouse button, when the cursor is positioned over
the parameter).
In order to configure a device via the SOPAS-ET configuration software, the respective
operating level has to be selected in advance. After the start, the SOPAS-ET
configuration software functions at the operating level "MAINTENANCE".
1. In the menu bar under TOOLS select the command LOGIN DEVICE.
2. In the dialog window under USERLEVEL in the list box select the entry
AUTHORIZED CLIENT.
If the parameter set is password-protected, enter the password "client" in
PASSWORD.
Activate/deactivate password protection on the PARAMETER register tab.
3. Click on OK to confirm the dialog window.
The previously greyed out parameters on the register tabs are now accessible.