For the Ethernet version of the RFH620, this input 2 is only available with the
connection module CDB620/CDM420 in combination with the parameter memory
module CMC600.
3.5.11 Digital Outputs
With certain events in the reading process (e.g. for unsuccessful decoding "No Read"),
two independent switch signals can be generated at both digital outputs and can be used,
e.g., to display the event status. The RFH620 “Ethernet-Version” do have two in the
antenna front integrated LEDs that are logical connected to the digital outputs. The
LEDs could be controlled via event result message or via command string send from the
host system.
The digital outputs could be configured using the SOPAS-ET configuration software:
PROJECT TREE, RFH620, PARAMETER, NETWORK / INTERFACE / IOS,
DIGITAL OUTPUTS
- or - via command language.
The switching outputs "Result 1" and "Result 2" are not only available on the RFH620
“Ethernet version”. The two outputs are only available with the connection module
CDB620/CDM420 in combination with the parameter memory module CMC600.
3.6 Indicators and control elements
3.5.1 User Interface
The RFH620 could be configured application-specifically using the SOPAS-ET
configuration software (see chapter “Overview of the startup procedure”). The software
for this runs on a PC which must be connected to data interfaces (aux interface: Ethernet
or RS-232, host interface: Ethernet) of the RFH620. As an alternative to the SOPAS-ET
configuration software, command strings are available upon which the user interface of
the SOPAS-ET configuration software is based.