CARRIER STUD PLACEMENT 

If using 

in-wall carrier, set bearing rods as 

shown above.

SET DRAIN LINE HEIGHT 

17” from  

finished floor (standard 24” rim) or 10” for 

ADA installation. Threaded nipple should 

extend ½ to ¾” from wall.

A. 

Clean face 

of existing wall flange. 

B.

 Install the brass flange

 with the 

clear inspection disc. 

C. 

Slowly pour water

 into the drain.

D.

 Use a flashlight to check the pitch/

slope

. No water should be present in 

the inspection disc or nipple. 

E. 

Remove flange

 after inspection.

DRILL HOLES 

with ⁵/₁₆"

 

masonry 

bit for the lower anchor screws 

and insert plastic anchors.

TIGHTEN COMPRESSION 

NUT AND GEAR CLAMP.

DETERMINE THE DRAIN NIPPLE DEPTH

 

by measuring the distance between the 

back of the sanitary tee (or elbow) to 

the front edge of the nipple.

MEASURE & MARK THE ROUGH-IN 

if 

in-wall carrier is not used. Use a ⁵/₁₆" 

masonry bit to drill hole, then install 

the hanger bracket with one plastic 

anchor and screw.

• 

Check rough-in height to achieve 24” 

rim height (17” rim height for ADA).

 Check slope. Downhill slope, per code, 

is essential because waterfree urinals 

require gravity flow for drainage.

 Check DWV material. Suitable materials 

include cast iron, PVC, ABS, and 

galvanized steel.

• Never install on copper DWV due to 

copper’s susceptibility to corrosion

.

• 

Measure drain nipple depth (in inches)

   to find trim length (in inches)

• 

13 

7 8

 “ or more

 DO NOT CUT TUBE

• 

3 ¾” or less

 DO NOT USE TUBE

BEFORE STARTING INSTALLATION

TUBE CUTTING CHART

OR LESS

TRIM

13 ¾"

¼

"

13 ½

½

13 ¼

¾

13

1

12 ¾

12 ½

12 ¼

12

2

11 ¾

11 ½

11 ¼

11

3

10 ¾

3 ¼

10 ½

3 ½

OR LESS

TRIM

10 ¼"

3 ¾

"

10

4

9 ¾

4 ¼

9 ½

4 ½

9 ¼

4 ¾

9

5

8 ¾"

5 ¼

8 ½

5 ½

8 ¼

5 ¾

8

6

7 ¾

6 ¼

7 ½

6 ½

7 ¼

6 ¾

7

7

OR LESS

TRIM   

6 ¾"

7 ¼

"

6 ½

7 ½

6 ¼

7 ¾

6

8

5 ¾

8 ¼

5 ½

8 ½

5 ¼

8 ¾

5

9

4 ¾

9 ¼

4 ½

9 ½

4 ¼

9 ¾

4

10

FLAX

NEW CONSTRUCTION 

INSTALLATION 

WATERFREE URINAL

866-975-0174 or 616-877-4805

[email protected]

CUSTOMER CARE

ADJUST DRAIN TO ACHIEVE PITCH 

only if standing water is present 

(code requires ¼” drop per foot of 

drain line for proper pitch). Seal wall 

according to code.

A.

 

Hang the bowl on the bracket 

and check tail 

pipe alignment, then remove the bowl and 

adjust the bracket as needed. 

 

Re-hang and re-check bowl  

alignment with 

the drain line.  Tail pipe should align with center 

of drain line. 

B.

 

Mark anchor holes 

then 

remove bowl without 

moving hanger bracket.

INCORRECT

Not centered

CORRECT

Centered

A

B

½"  

to

 ¾"

9¾" 

for ADA 

installation

standard 24" rim

finished floor 

16 ¾"

11⁄8

1"

151⁄8"

Drain

Cut away wall

Lift drain line & brace 

with mending plate

151⁄8"

 

Install plastic anchor 

and screw here

11

10

12

Install two 

additional screws

A.

 

Find the drain nipple depth

 on 

the Tube Cutting Chart (left).

 

Measure and mark the specified 

trim length 

on the insert tube at 

the nearest ¼” groove.

B.

 

Cut the tube

 at the groove using a sharp 

utility knife to ensure a square, flat cut. 

C.

 

Clean burrs 

from the cut end by using 

emery paper.

D.

 

Apply lubricant

 to the outside of the 

rubber bushing and ribbed inside area. 

E.

 

Insert the tube 

and bushing with arrow 

tab at the top. Apply lubricant to tailpipe 

of housing.

1

2

3

4

Arrow 
tab UP

1

2

3

4

A

C

B

D

E

POUR 5 

GALLONS 

OF WATER

 

as rapidly 

as possible 

into housing 

to ensure 

good flow 

and no leaks or 

standing water.

CAULK THE BOWL 

TO THE WALL 

if 

there is good flow 

and no leaks or 

standing water.

INSTALL 

CARTRIDGE

 

per the cartridge 

instruction sheet.

CARTRIDGE 

INSTRUCTIONS

HANG THE BOWL,

 inserting tailpipe 

into bushing, then install anchor 

screws with washers.

 TIGHTEN 

FLANGE BOLTS. 

The information in this document is 

subject to change without notice.  

©2014 Falcon Waterfree Technologies, 

LLC. All rights reserved. 

FalconWaterfree.com

CAUTION

 After removing any urinal from the 

drain line, it’s normal for certain naturally occurring 

but

 potentially hazardous sewer gases 

to escape 

through the opening until the waterless cartridge 

is installed properly into the waterless urinal. If you 

need to leave an open drain line unattended after 

removing the urinal from the wall, temporarily wedge paper towels or a 

rag into the drain hole to reduce any outflow of sewer gases, and remove 

the paper towels or rag prior to completing the urinal or cartridge 

installation. 

Never smoke, have an open flame, or place your nose or 

mouth near open drain lines or waterless urinal housings into which 

a cartridge is not yet properly installed. 

You also can wear a breathing 

mask when removing or installing any waterless urinal or cartridge to 

reduce potential exposure to any such gases.

PLACE THE GEAR CLAMP 

and compression nut onto the 

housing tailpipe.

14

15

4

13

3

12

8

6

2

10

11

7

5

1

C

D

9