3.2.2
Variants
The safety laser scanner is delivered in different variants. You will find an overview of
important distinguishing features of the variants in the following.
Performance package
The Core performance package is characterized by the number of configurable fields
and the number of safety switching functions (OSSD pairs).
•
outdoorScan3 core I/O: 8 fields; safety output: 1 OSSD pair
Integration in the control
The safety laser scanner communicates with the machine controller as follows:
•
I/O: local inputs and outputs (incl. OSSDs)
The safety laser scanner is available in variants with the following maximum protective
field range:
•
4.0 m
Further topics
•
3.2.3
Status indicators
The safety laser scanner outputs important status information using a number of light
emitting diodes. The safety laser scanner has a graphical display and 4 pushbuttons for
additional information.
4 status light emitting diodes are located directly above the display.
1
2
3
4
Figure 5: Status LEDs
Table 2: Status LEDs
Number
Function
Color
Meaning
1
Red
Lights up red when the OSSD pair is
in the OFF state.
2
Green
Lights up green when the OSSD pair
is in the ON state.
3
Yellow
Shines yellow if at least one warning
field is interrupted.
4
Yellow
Setup with reset: Flashes if the
restart interlock has been triggered.
Configuration with automated restart
after a time: Lights up while the con‐
figured time to restart expires.
3
PRODUCT DESCRIPTION
16
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/160F/2019-11-14 | SICK
Subject to change without notice