Restarting safety function and connections
•
The device’s function is also re-established after serious faults if the cause has
been rectified.
•
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety). The device sets up communication
again automatically after restarting.
•
Communication beyond the device is not impaired.
Restarting device completely
•
The device behaves exactly as it does when the voltage supply is switched off and
back on again.
•
The device’s function is also re-established after serious faults if the cause has
been rectified.
•
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety).
•
Communication beyond the device is interrupted. This may also affect devices
which communicate beyond the device.
7.15.2
Factory settings
Before reconfiguring the device, you can reset all settings to factory settings.
Reseting safety function to factory settings
•
The configuration for the safety function is reset to factory settings.
•
Communication beyond the device is not impaired.
Reseting whole device to factory settings
•
The configuration for the safety function is reset to factory settings.
•
The configuration of device communication is reset to factory settings (connec‐
tions for configuration, safety function and data not relating to safety).
7.15.3
Managing passwords
Assigning or changing passwords
1.
Establish a connection to the device.
2.
In the device window, under
Service
, choose the entry
User password
.
3.
Choose the user group in the
User password
dialog box.
4.
Enter the new password twice and use
Accept
to confirm.
5.
If you are requested to log in, log in as an
Authorized customer
.
✓
The new password is valid for the user group immediately.
Resetting a password
If you have forgotten a password, you can reset it.
1.
Request the form for resetting your password from SICK support.
2.
Connect to the device in Safety Designer.
3.
In the device window, under
Service
, choose the entry
User password
.
4.
Choose the
Reset password
option in the
User password
dialog box.
5.
Transmit the serial number shown and the device counter together with the prod‐
uct number and the type code on the form to SICK support.
✓
You will then receive a reset code.
6.
Enter the reset code under
Password reset
and use
Accept
to confirm.
✓
The passwords are reset to factory settings (SICKSAFE for an
authorized client
, no
password for
machine operators
. It is not possible for
maintenance technicians
to log
in). The configuration is not changed.
7
CONFIGURATION
100
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/160F/2019-11-14 | SICK
Subject to change without notice