1
2
3
4
Figure 63: Status LEDs
Table 16: Status LEDs
Number
Function
Color
Meaning
1
Red
Lights up red when the OSSD pair is
in the OFF state.
2
Green
Lights up green when the OSSD pair
is in the ON state.
3
Yellow
Shines yellow if at least one warning
field is interrupted.
4
Yellow
Setup with reset: Flashes if the
restart interlock has been triggered.
Configuration with automated restart
after a time: Lights up while the con‐
figured time to restart expires.
The OFF state and ON state light emitting diodes can be found in multiple locations on
the safety laser scanner. 3 additional sets are arranged in pairs on the base of the
optics cover. So the light emitting diodes can also be seen in many cases when it is not
possible to see the display, e.g. due to the mounting situation or because it is hidden
from the operator’s position.
9.4
Buttons and display
The safety laser scanner is equipped with 4 pushbuttons and a graphical display. You
can use the buttons to show information on the display and make simple settings.
NOTE
The display language is set using Safety Designer during configuration. The display lan‐
guage and the configuration cannot be changed using the buttons on the display.
9
OPERATION
106
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/160F/2019-11-14 | SICK
Subject to change without notice