NOTICE
Enclosure rating IP65 only applies if the safety laser scanner is closed and the system
plug is mounted.
b
Mount the system plug.
b
Close the M12 plug connector on the safety laser scanner using a male cable con‐
nector or a protective cap.
°
Tightening torque for plug connector: 0.4 Nm … 0.6 Nm.
°
Tightening torque for protective caps: 0.6 Nm … 0.7 Nm.
b
When mounting the connecting cable, ensure the seals are intact and seated cor‐
rectly.
6.2
Connection overview
The USB connection may only be used temporarily and only for configuration and diag‐
nostics. The permanent connections are contacted via M12 plug connectors.
6.2.1
outdoorScan3 Core
Table 6: System plug and connections
Safety laser scanner
Suitable system plug
Plug connector
outdoorScan3 Core I/O
MICSX-UBIZZZZZ1 (part number: 2101638)
•
Connecting cable with M12 plug
connector,
6.3
Pin assignment
You will find the pin assignment for the individual plug connectors in the following.
6.3.1
Connecting cable with M12 plug connector
Voltage is supplied and local inputs and outputs are connected via the connecting
cable with an 8-pin, A-coded M12 male connector.
The connecting cable must be protected against UV radiation, e.g., by using a weather
hood or by mounting the device in a protected area of the vehicle or machine.
8
2
3
4
5
7
1
6
Figure 41: Pin assignment of the connecting cable (male connector, M12, 8-pin, A-coded)
6
ELECTRICAL INSTALLATION
64
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/160F/2019-11-14 | SICK
Subject to change without notice